Delta
Field hub — common codes, ownership boundaries, and links into the fault database.
Delta — field brand hub
Delta tickets in this corpus center on UFC-class DC fast chargers. Ground fault, backend unreachable, exhaust fan faults, and connector lock motor failures dominate. Verify grid and fan path before isolation-style RMAs, and split soft-offline backend from true protective GF. Name UFC and whether the stall is alone or pad-wide before opening HV.
When this OEM shows up / cabinet vs dispenser
UFC packages combine power conversion, cooling/exhaust, connector lock, and OCPP/backend connectivity. Ownership:
Protective / PE side: Ground fault under rain or wash-down—dry and prove PE before board swaps.
Thermal / airflow side: Exhaust fan fault driving derate or Faulted—filters and fan hardware before sensor theater.
Lock / connector side: Lock motor fail at Preparing—mechanical debris vs actuator.
Backend / network side: Backend unreachable with local Ready possible—DNS/TLS/CSMS path, not a power module.
Do not treat backend unreachable as “charger dead” without Heartbeat evidence. Do not clear GF repeatedly into a wet fault.
How faults typically present
HMI
- UFC banners (DEL-UFC-*).
- GF latch that returns immediately after clear.
- Fan fault / overtemp derate before hard Faulted.
- Lock fail with gun not seating.
OCPP / backend
- Faulted GroundFailure—use /guides/ocpp-faulted-triage.
- Soft-offline: Heartbeat timeout / Unavailable while local may look Ready (/entries/protocol-ocpp-f02-heartbeat-timeout-to-csms).
- DNS/TLS path: /entries/protocol-net-c01-dns-resolution-failure-to-csms.
- Modem RSSI in metal cabinets: /entries/sierra-wireless-mdm-rssi-rssi-too-low-in-cabinet.
Physical cues
- Wet holster after rain, blocked exhaust, grinding lock motor, antenna inside shielded door, recent SIM swap.
Ranked common failure patterns
-
UFC ground fault — Moisture bridging GF sensing or true PE fault. Free sample: /entries/delta-del-ufc-gf-ufc-ground-fault. PE continuity: /entries/protocol-gnd-01-ground-continuity-fail-at-dispenser.
-
Backend unreachable — CSMS/DNS/TLS/modem path; energy hardware may be fine. Free sample: /entries/delta-del-ufc-com-backend-unreachable. Prove Heartbeat and URL/certs before power-stage blame.
-
Exhaust fan fault — Filter, seized fan, or sensor. Entry: /entries/delta-del-ufc-fan-exhaust-fan-fault. Thermal siblings: /entries/protocol-temp-01-connector-overtemp-derate when derate presents at the gun.
-
Connector lock motor fail — Debris, ice, worn actuator, or feedback switch—second vehicle before board RMA. Entry: /entries/delta-del-ufc-lock-connector-lock-motor-fail. CCS latch cousins: /guides/ccs-handshake-basics.
Log sources / tools
| Source | What you pull |
|---|---|
| UFC HMI / LEDs | GF, fan, lock, backend status |
| OCPP / CSMS | Heartbeat gaps, StatusNotification, BootNotification |
| Modem / ALEOS if present | RSSI/RSRP vs disconnect times |
| DMM / known-good cable | PE, lock continuity, isolation if ISO also present |
Field checklist (first 15 minutes)
- Photo HMI + connector ID; one stall or whole pad?
- GF vs backend vs fan vs lock—name the branch.
- Weather / wash-down / recent SIM or antenna work?
- If GF: dry; PE measure; one clear after cause—not spam resets.
- If backend: Heartbeat, DNS, TLS, RSSI before module crates.
- If fan: inlet/exhaust clear; listen for seize.
- If lock: inspect tongue; second vehicle; then actuator path.
When to escalate
Electrician — Open PE, feeder GF upstream, undervoltage clusters (/guides/site-power-quality-basics).
Network / CSMS — Backend unreachable with healthy RF after antenna prove; wrong OCPP identity after board work.
Delta OEM — Confirmed GF board after dry/PE; fan assembly after airflow proven; lock motor after mechanical prove.
Do not escalate soft-offline as GF, or lock fail as a power-module fault. Payment-only issues belong to PED (/guides/metering-payment), not UFC exhaust fans.
Worked examples
Example A — GF under rain, returns after clear. Dry holster/cable; measure PE. One OEM clear after cause—not ten resets.
Example B — Cloud red, local Ready, fan quiet OK. Backend unreachable / Heartbeat path. Check DNS, TLS, modem RSSI before exhaust-fan RMA.
Example C — Derate then fan fault banner. Clear filters; confirm fan spin. Do not megger for isolation first.
Example D — Lock motor grind at Preparing; second car same. Actuator/debris. Peer connector healthy means not “whole UFC dead.”
False friends
| Looks like | Often actually |
|---|---|
| Dead power stage | Soft-offline backend |
| Isolation board | GF moisture / PE open |
| SECC fail | Lock motor mechanical |
| Antenna bad | Wrong OCPP URL after board swap |
Related learning
/learn/reading-ocpp-statusnotification · /learn/safety-loto-boundary · /help
Ticket hygiene
Capture: HMI photo, connector/port ID, peer status, OCPP errorCode + vendor string verbatim, weather/service notes, and (for thermal/grid) a loaded measurement. Scrub customer PII before /request or Pro Q&A. Prefer one branch per ticket—do not merge money-path and HV into one RMA narrative.
Coordination notes
When opening OEM or electrician tickets, attach: HMI photos, connector IDs, OCPP vendor strings, peer-stall status, and any loaded voltage or RF measurements. That evidence pack cuts “replace module” ping-pong. Keep one fault branch per work order.
Platform notes (UFC)
UFC soft-offline is easy to misread as a dead power stage because Cloud is red. Always ask whether local Ready and whether a local start still works. Exhaust paths clog after storms and cottonwood season—fan faults spike then. Lock motors fail more in freezing rain than in dry heat. GF clears that return in under a minute are hard latches: stop resetting and measure PE. Pair backend tickets with modem RSSI history when the cabinet is metal.
Models
Fault index (4)
DEL-UFC-GFDelta · UFC100 · DC Fast ChargersFree sampleUFC ground fault
Delta UFC100 dispenser trips ground fault mid-session or during CableCheck, most often after rain, wash-down, or a recent cable service call. HMI banner reads Ground Fault while OCPP reports Faulted/GroundFailure; the fault can lock a single gun or take the whole cabinet Unavailable if the sensing sits upstream of the split.
DEL-UFC-COMDelta · UFC100 · DC Fast ChargersFree sampleBackend unreachable
Delta UFC100 loses its link to CSMS/cloud while the local HMI may still show Ready or Available, creating a mismatch where drivers see a working screen but the backend lists the station offline or flapping. Heartbeat gaps and delayed StatusNotification are the giveaway; sessions started locally may not sync until the link recovers.
DEL-UFC-FANDelta · UFC100 · DC Fast Chargers solo+Exhaust fan fault
Delta UFC100 exhaust fan fault raises internal cabinet temperature during high-power sessions, first showing as a derate…
DEL-UFC-LOCKDelta · UFC100 · DC Fast Chargers solo+Connector lock motor fail
Delta UFC100 connector lock motor fails to latch or release the CCS handle, leaving a session unable to start or a cable…