CMS-OCPPAmpcontrol · Fleet CMS solo+

CMS-OCPP mapping wrong connector

The CMS's connector mapping doesn't match reality — a driver plugged into stall A is authorized, billed, and tracked as …

1 confirmed
CMS-SCHEDAmpcontrol · Fleet CMS solo+

Schedule blocks depot overnight

A CMS charging schedule policy is blocking sessions overnight exactly as configured, so drivers plug in at 2 AM and repo…

1 confirmed
CMS-APIAmpcontrol · Fleet CMS solo+

API key revoked mid-shift

A CMS or CSMS API key gets revoked or rotated mid-shift, and every integration that depends on it stops working simultan…

2 confirmed
CMS-TZAmpcontrol · Fleet CMS solo+

Timezone skew mis-schedules

A timezone configuration mismatch causes schedules to fire hours early or late — this most commonly appears right after …

1 confirmed
BESS-PCSFluence / BESS · BESS solo+

PCS fault blocks discharge to EVSE

A power conversion system (PCS) fault opens the contactors that connect the BESS to the EVSE bus, so chargers lose their…

1 confirmed
BESS-FIREFluence / BESS · BESS solo+

Fire panel inhibits charge

The fire alarm control panel (FACP) is holding an inhibit on the BESS/EVSE charge and discharge path, locking out charge…

1 confirmed
SWG-CTEaton · Switchgear solo+

CT wiring reversed after CT swap

A current transformer (CT) was recently swapped and its wiring is reversed — metering, load management, or protection sy…

3 confirmed
CMS-VEHAmpcontrol · Fleet CMS solo+

VIN not in fleet allowlist

A vehicle's VIN isn't in the fleet allowlist, so Plug&Charge or VIN-based authorization fails outright for a new bus or …

1 confirmed
CMS-PRICEAmpcontrol · Fleet CMS solo+

Tariff push fails — sessions free

A tariff push from the CMS to the CSMS fails silently, so sessions run for free or bill at a stale rate — drivers are ha…

2 confirmed
BESS-BALFluence / BESS · BESS solo+

Cell imbalance inhibits output

Cell or module imbalance within the BESS is limiting or fully blocking discharge output to the EVSE bus, so chargers eit…

3 confirmed
SWG-UPSEaton · Switchgear solo+

Controls UPS dead — gear won't close

The switchgear's controls UPS is dead, so protective relays are dark and the gear cannot be commanded to close even thou…

2 confirmed
CMS-OFFAmpcontrol · Fleet CMS solo+

CMS offline — local fallback weak

When the CMS or its cloud path goes offline, the local fallback authorization is too weak to cover it — chargers refuse …

1 confirmed