Site stack (generic)

Field hub — common codes, ownership boundaries, and links into the fault database.

Contactors, SPD/RCD, coolant skids, LMS cabinets, and cable IR — OEM-agnostic site stack that fails independently of charger brand. Prove this layer before OEM RMA.

Models

Fault index (24)

CTR-WELDSite stack (generic) · Contactors & protectionFree sample

Main DC contactor welded

Main DC contactor welded — weld detect or stuck-closed feedback after high-cycle use; do not force energy. site-generic field note: keep evidence scrubbed and prove the ranked cause before module RMA on CTR-WELD.

1 confirmed
CTR-COILSite stack (generic) · Contactors & protection solo+

Contactor coil open

Contactor coil open — contactor will not pull in; coil circuit open or driver failed. site-generic field note: keep evid…

2 confirmed
BRK-TRIPSite stack (generic) · Contactors & protection solo+

Feeder breaker nuisance trip

Feeder breaker nuisance trip — pad or cabinet feeder opens under EVSE ramp; often PQ/settings not a single module. site-…

3 confirmed
SPD-FAILSite stack (generic) · Contactors & protection solo+

SPD end-of-life indicated

SPD end-of-life indicated — surge protector flag/window shows spent; replace before the next surge event. site-generic f…

2 confirmed
RCD-TESTSite stack (generic) · Contactors & protection solo+

RCD fails monthly test

RCD fails monthly test — protective device does not trip on test or will not reset; treat as protection failure. site-ge…

2 confirmed
COOL-PUMPSite stack (generic) · Coolant skid · Liquid cooling solo+

Coolant pump no flow

Coolant pump no flow — pump alarm/thermal derate with zero inferred flow on liquid-cooled skid. site-generic field note:…

3 confirmed
COOL-LEAKSite stack (generic) · Coolant skid · Liquid cooling solo+

Glycol leak at quick-connect

Glycol leak at quick-connect — visible drip or pressure loss at gun/skid QD after cable work. site-generic field note: k…

3 confirmed
COOL-AIRSite stack (generic) · Coolant skid · Liquid cooling solo+

Airlocked loop after fill

Airlocked loop after fill — pump runs but cooling ineffective until bleed removes air. site-generic field note: keep evi…

1 confirmed
COOL-SENSSite stack (generic) · Coolant skid · Liquid cooling solo+

Flow sensor false low

Flow sensor false low — cooling actually fine by IR/pressure but sensor reports low flow. site-generic field note: keep …

1 confirmed
CAB-IRSite stack (generic) · Cables & connectors solo+

Cable IR insulation fail

Cable IR insulation fail — insulation resistance below OEM limit on DC cable path. site-generic field note: keep evidenc…

2 confirmed
CAB-PINSite stack (generic) · Cables & connectors solo+

CCS pin burnt

CCS pin burnt — overheating/arcing damage on power pins from high resistance or partial latch. site-generic field note: …

1 confirmed
CAB-LATCHSite stack (generic) · Cables & connectors solo+

Latch microswitch false open

Latch microswitch false open — charger thinks latch open while mechanically latched. site-generic field note: keep evide…

3 confirmed
CAB-STRAINSite stack (generic) · Cables & connectors solo+

Strain relief broken

Strain relief broken — cable jacket control failed; conductors flex/fatigue at gland. site-generic field note: keep evid…

1 confirmed
LMS-ZEROSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

LMS allocates 0 A all ports

LMS allocates 0 A all ports — site controller sets zero budget; stalls idle with healthy hardware. site-generic field no…

1 confirmed
LMS-COMSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

LMS PLC offline

LMS PLC offline — chargers lose LMS and enter failsafe curtail/Unavailable. site-generic field note: keep evidence scrub…

3 confirmed
CAB-FANSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

Power cabinet fan fail

Power cabinet fan fail — thermal alarms with stopped or noisy cabinet fans on the site power cabinet, often after dusty …

1 confirmed
CAB-BUSSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

DC bus undervoltage

DC bus undervoltage — bus collapses under load from grid/feed or module issues. site-generic field note: keep evidence s…

2 confirmed
CAB-PARSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

Parallel cabinet sync fail

Parallel cabinet sync fail — paralleled cabinets refuse to share or sync DC bus. site-generic field note: keep evidence …

3 confirmed
CAB-NACSSite stack (generic) · Cables & connectors solo+

NACS handle overtemp

NACS handle overtemp — NACS path thermal derate/fault from handle or inlet heat. site-generic field note: keep evidence …

2 confirmed
CTR-AUXSite stack (generic) · Contactors & protection solo+

Aux contact feedback mismatch

Aux contact feedback mismatch — controller sees disagreement between command and aux, blocking sessions. site-generic fi…

2 confirmed
DEP-CURTSite stack (generic) · Power cabinet / LMS solo+

Depot LMS curtails on demand response

Depot LMS curtails on demand response — scheduled DR event cuts amps across the depot. site-generic field note: keep evi…

1 confirmed
DEP-SEQSite stack (generic) · Power cabinet / LMS solo+

Sequential start brownout

Sequential start brownout — too many stalls authorize together; voltage sag trips protection. site-generic field note: k…

2 confirmed
DEP-ISLANDSite stack (generic) · BESS solo+

Island mode leaves EVSE dark

Island mode leaves EVSE dark — site generation/BESS island excludes EVSE bus or opens intertie. site-generic field note:…

1 confirmed
DEP-XFMR-TAPSite stack (generic) · Switchgear solo+

Wrong tap leaves undervoltage

Wrong tap leaves undervoltage — transformer tap leaves EVSE bus low under load. site-generic field note: keep evidence s…

1 confirmed