Wallbox
Field hub — common codes, ownership boundaries, and links into the fault database.
Wallbox — field brand hub
Wallbox tickets in this corpus center on Pulsar Plus AC wallboxes (workplace / residential / light commercial). There is no DC cabinet↔dispenser split — ownership is enclosure, CP/pilot path, GFCI/PEN protection, and Wi-Fi/app schedule.
When this OEM shows up
Expect GFCI trips after rain or wash-down, CP state faults with no EV, UK-style PEN faults on relevant installs, and Wi-Fi drops that kill scheduled charging. Confirm whether the complaint is “won’t start,” “trips mid-session,” or “schedule didn’t run” before opening the enclosure. Wall unit owns GFCI, PP/CP, and local UI. Site owns feeder breaker, PE bond, and often the Wi-Fi/AP path. Do not open the EVSE for a tripped upstream breaker that only looks like a charger fault.
How faults present
- Local LEDs / app: fault icons, GFCI trip, CP error.
- OCPP (networked installs): Faulted / Unavailable; schedule failures may stay Available with no session — check app/backend, not just StatusNotification. Use /guides/ocpp-faulted-triage when Faulted.
- Cloud / myWallbox-class app: schedule and Wi-Fi history often explain “didn’t charge overnight.”
- Physical: moisture at cable gland, wet holster after wash-down, weak Wi-Fi after AP changes.
Ranked failure patterns
-
Pulsar GFCI trip — Moisture, contamination, or true ground path. Dry and inspect before board swaps. Entry: /entries/wallbox-wb-pp-gfci-pulsar-gfci-trip. PE: /entries/protocol-gnd-01-ground-continuity-fail-at-dispenser.
-
CP state fault, no EV — Pilot wiring, diode path, or stuck state with nothing plugged. Prove with second vehicle/cable when possible. Entry: /entries/wallbox-wb-pp-cp-cp-state-fault-no-ev.
-
PEN fault (UK-style) — Protective earth/neutral monitoring on applicable installs — electrician territory if wiring. Entry: /entries/wallbox-wb-pp-pen-pen-fault-uk-style.
-
Wi-Fi drop loses schedule — AP coverage / credentials; energy path may be fine. Entry: /entries/wallbox-wb-pp-wifi-wi-fi-drop-loses-schedule. Soft-offline Heartbeat gaps: /entries/protocol-ocpp-f02-heartbeat-timeout-to-csms.
Logs / tools
App/cloud event history, LED state photos, DMM on CP/PE, outlet/breaker verification, known-good cable/vehicle. For networked OCPP sites: Heartbeat and StatusNotification export.
Escalate when
- Electrician: PEN/PE, breaker, supply voltage, wet conduit, shared-circuit trips under load.
- Network/site IT: Wi-Fi/SSID changes, VLAN, captive portal.
- OEM: Confirmed CP board / GFCI hardware after wiring and moisture cleared.
Do not OEM-escalate schedule misses that are Wi-Fi only.
Field checklist
- Breaker tripped or EVSE GFCI? Check upstream first.
- Schedule miss vs hard fault — pull app Wi-Fi history.
- Photo LEDs; note weather / wash-down.
- Known-good cable/vehicle if CP or GFCI.
- PEN/PE issues: stop and call electrician on applicable installs.
- Networked sites: OCPP Heartbeat vs local charge capability.
Keep GFCI, CP, PEN, and Wi-Fi as separate ticket paths — do not combine them into one board RMA.
Models
Fault index (4)
WB-PP-GFCIWallbox · Pulsar Plus · AC Level 2Free samplePulsar GFCI trip
Wallbox Pulsar trips GFCI/RCD during rain, wash-down, or cable handling. App/HMI shows ground-fault or protection trip; breaker may also open. Session will not restart until the protective device is reset and the moisture/insulation cause is cleared—not just the reset button mashed.
WB-PP-WIFIWallbox · Pulsar Plus · AC Level 2 solo+Wi-Fi drop loses schedule
Wallbox Pulsar Plus drops its Wi-Fi connection: scheduled charging and cloud-based authorization stop working while a lo…
WB-PP-CPWallbox · Pulsar Plus · AC Level 2 solo+CP state fault no EV
Wallbox Pulsar Plus reports a control-pilot state fault with no vehicle plugged in, or the unit never advances past Stat…
WB-PP-PENWallbox · Pulsar Plus · AC Level 2 solo+PEN fault UK-style
UK-style Wallbox Pulsar Plus units with PEN-fault protection trip or inhibit charging entirely when the supply's protect…