Arcbound Field · Field sheet · Wallbox · WB-PP-GFCI
WB-PP-GFCIPulsar GFCI trip
Wallbox · Pulsar Plus · AC Level 2
Safety
Qualified EVSE personnel only. Follow site LOTO and OEM HV / arc-flash boundaries. Insulation and ground tests have their own hazards — use rated testers and OEM limits. Not a substitute for OEM service manuals or AHJ requirements.
How it presents
- Display
- Pulsar GFCI trip
Symptom
Pulsar GFCI trip on wallbox (pulsar-plus): myWallbox / LED ring shows WB-PP-GFCI. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate Wallbox cloud + OCPP if networked before opening the cabinet.
Root causes (by observed frequency)
- #1 Moisture or contamination bridging ground-fault sensing on WB-PP-GFCI
Rain, wash-down, or failed cable boot seals rank highest on outdoor DCFC
- #2 True equipment ground path open or high-impedance bond at pedestal
- #3 Nuisance trip from EMI / filter aging after power-module work
Diagnostic procedure
1. Capture myWallbox / LED ring message for WB-PP-GFCI, connector ID, and last successful session time
Expected: Exact display string + OCPP status/errorInfo if present
Tools: phone photos (scrubbed), CSMS
2. Pull Wallbox cloud + OCPP if networked; confirm whether Pulsar GFCI trip follows one gun, one cabinet, or the whole site
Expected: Fault correlates to one path
Tools: CSMS export, OEM cloud
3. On model pulsar-plus hardware, isolate power quality / protective devices before opening HV for WB-PP-GFCI
Expected: Voltage in band; no unexpected trips
Tools: DMM, IR gun, LOTO kit
4. Execute rank-1 cause check for “Pulsar GFCI trip”; swap known-good cable/gun or stall if available
Expected: Fault moves with cable or stays with cabinet
Tools: known-good cable, IR, OEM service menu
5. If unresolved, escalate with WB-PP-GFCI evidence pack (HMI photo, OCPP snippet, readings) — Confirm CP duty and breaker before board swap on Pulsar-class
Tools: ticket template
The fix
Clear WB-PP-GFCI (Pulsar GFCI trip) by correcting the ranked cause on wallbox / pulsar-plus, then run a full validation session.
Suspect module or controller indicated by rank-1 cause
OEM wallbox service channel; keep serial for RMA
WB-PP-GFCI
- LOTO and verify zero energy per wallbox HV procedure before any bus work
- Correct rank-1 cause for WB-PP-GFCI; do not shotgun-replace modules
- Clear fault latches in HMI/CSMS; confirm StatusNotification returns to Available/Preparing as appropriate
- Run validation: authorize → handshake → ≥5 minutes energy → clean stop; capture MeterValues
- Document firmware, part lots, and scrubbed HMI photos for confirmations