CCS-H01Cross-brand / Protocol · Cables & connectorsFree sample

CCS SLAC timeout

CCS SLAC timeout (CCS-H01) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H02Cross-brand / Protocol · Cables & connectorsFree sample

SDP failed — SECC not responding

SDP failed — SECC not responding (CCS-H02) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
CCS-H03Cross-brand / Protocol · Cables & connectorsFree sample

Cable check isolation fail

Cable check isolation fail (CCS-H03) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H04Cross-brand / Protocol · Cables & connectorsFree sample

Precharge voltage mismatch

Precharge voltage mismatch (CCS-H04) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
CCS-H05Cross-brand / Protocol · Cables & connectorsFree sample

Power delivery stops at CurrentDemand

Power delivery stops at CurrentDemand (CCS-H05) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
CCS-H06Cross-brand / Protocol · Cables & connectorsFree sample

Welding detection trip

Welding detection trip (CCS-H06) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H07Cross-brand / Protocol · Cables & connectorsFree sample

PP resistor out of range

PP resistor out of range (CCS-H07) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H08Cross-brand / Protocol · Cables & connectorsFree sample

CP state B stuck

CP state B stuck (CCS-H08) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
SEQ-01Cross-brand / Protocol · Cables & connectorsFree sample

EVSE ready before vehicle CP ready race

EVSE ready before vehicle CP ready race (SEQ-01) — Sequence / interlock field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
VEH-X01Cross-brand / Protocol · Cables & connectors solo+

Known vehicle profile needs CCS pause workaround

Known vehicle profile needs CCS pause workaround (VEH-X01) — Vehicle profile field fault. Stay OEM-agnostic until the pr…

1 confirmed
CCS-H09Cross-brand / Protocol · Cables & connectorsFree sample

SECC discovery wrong IP

SECC discovery wrong IP — vehicle cannot find SECC on the expected link-local/IP path; handshake dies at discovery/SDP. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on CCS-H09.

2 confirmed
CCS-H10Cross-brand / Protocol · Cables & connectorsFree sample

SessionSetup ResponseCode Failed

SessionSetup ResponseCode Failed (CCS-H10) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H11Cross-brand / Protocol · Cables & connectorsFree sample

EVSideCableCheck unknown error

EVSideCableCheck unknown error (CCS-H11) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
ABB-T54-CCSABB · Terra 54 · DC Fast ChargersFree sample

CCS connector latch fail

Terra 54 CCS connector latch fail — mechanical latch/actuator before SECC condemnation. Field techs should correlate HMI/Cloud timestamps with Verify which gun and which stack faulted on dual-standard Terra sites.

3 confirmed
TRI-PK-GUNTritium · PK350 · DC Fast Chargers solo+

Gun temperature derate

PK gun temperature derate — handle/contact heat or sensor; sun and damaged guns rank high. Field techs should correlate …

3 confirmed
KEM-SAT-CCSKempower · Satellite · DC Fast Chargers solo+

CCS session abort mid-ramp

Kempower CCS session abort mid-ramp — handshake/current share under dynamic pool assignment. Field techs should correlat…

1 confirmed
CAB-PINSite stack (generic) · Cables & connectors solo+

CCS pin burnt

CCS pin burnt — overheating/arcing damage on power pins from high resistance or partial latch. site-generic field note: …

1 confirmed