Arcbound Field · Field sheet · Cross-brand / Protocol · CCS-H03
CCS-H03Cable check isolation fail
Cross-brand / Protocol · Cables & connectors
Safety
Qualified EVSE personnel only. Follow site LOTO and OEM HV / arc-flash boundaries. Insulation and ground tests have their own hazards — use rated testers and OEM limits. Not a substitute for OEM service manuals or AHJ requirements.
How it presents
- Display
- Cable check isolation fail
Symptom
Cable check isolation fail on protocol: CSMS StatusNotification + connector LEDs shows CCS-H03. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate OCPP websocket / SECC / vehicle logs as applicable before opening the cabinet.
Root causes (by observed frequency)
- #1 Cable or gun insulation breakdown presenting as CCS-H03
Swap known-good cooled/uncooled cable before condemning power stage
- #2 Coolant contamination or leak wetting DC bus sensors
- #3 Y-cap / filter path degraded after surge or grid event
Diagnostic procedure
1. Capture CSMS StatusNotification + connector LEDs message for CCS-H03, connector ID, and last successful session time
Expected: Exact display string + OCPP status/errorInfo if present
Tools: phone photos (scrubbed), CSMS
2. Pull OCPP websocket / SECC / vehicle logs as applicable; confirm whether Cable check isolation fail follows one gun, one cabinet, or the whole site
Expected: Fault correlates to one path
Tools: CSMS export, OEM cloud
3. On hardware, isolate power quality / protective devices before opening HV for CCS-H03
Expected: Voltage in band; no unexpected trips
Tools: DMM, IR gun, LOTO kit
4. Execute rank-1 cause check for “Cable check isolation fail”; swap known-good cable/gun or stall if available
Expected: Fault moves with cable or stays with cabinet
Tools: known-good cable, IR, OEM service menu
5. If unresolved, escalate with CCS-H03 evidence pack (HMI photo, OCPP snippet, readings) — Stay OEM-agnostic until the protocol stage pins a hardware path
Tools: ticket template
The fix
Clear CCS-H03 (Cable check isolation fail) by correcting the ranked cause on protocol, then run a full validation session.
DC cable / gun assembly
Match cooled vs uncooled; OEM-approved only
protocol-cable-std
Suspect module or controller indicated by rank-1 cause
OEM protocol service channel; keep serial for RMA
CCS-H03
- LOTO and verify zero energy per protocol HV procedure before any bus work
- Correct rank-1 cause for CCS-H03; do not shotgun-replace modules
- Clear fault latches in HMI/CSMS; confirm StatusNotification returns to Available/Preparing as appropriate
- Run validation: authorize → handshake → ≥5 minutes energy → clean stop; capture MeterValues
- Document firmware, part lots, and scrubbed HMI photos for confirmations