The EVSE DirectorySubscribe

Fault database

Search by code, symptom, brand, category, or connector. Full procedures gated by subscription — look for green Free sample badges for open procedures.

Viewing as free

7 results

OCPP-F08Cross-brand / Protocol · DC Fast ChargersFree sample

BootNotification rejected — wrong chargePointModel

BootNotification rejected — wrong chargePointModel / identity after board swap or clone config, leaving the charger offline to CSMS. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on OCPP-F08.

3 confirmed
CFG-01Cross-brand / Protocol · DC Fast ChargersFree sample

Wrong OCPP URL after board swap

Wrong OCPP URL after board swap — new controller still points at lab/staging or old CSMS, so production Cloud never sees the charger. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on CFG-01.

3 confirmed
CFG-02Cross-brand / Protocol · DC Fast ChargersFree sample

Connector ID mismatch dual-gun cabinet

Connector ID mismatch dual-gun cabinet (CFG-02) — Configuration field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CFG-03Cross-brand / Protocol · DC Fast ChargersFree sample

Power module map incorrect after expansion

Power module map incorrect after expansion (CFG-03) — Configuration field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CFG-04Cross-brand / Protocol · DC Fast ChargersFree sample

Wrong timezone breaks TOU LMS

Wrong timezone breaks TOU LMS (CFG-04) — Configuration field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
DEP-XFMR-TAPSite stack (generic) · Switchgear solo+

Wrong tap leaves undervoltage

Wrong tap leaves undervoltage — transformer tap leaves EVSE bus low under load. site-generic field note: keep evidence s…

1 confirmed
SCH-EV-CFGSchneider Electric · EVlink · AC Level 2 solo+

Wrong max current config

Schneider EVlink either trips its upstream breaker repeatedly or delivers charging stuck at an unexpectedly low amperage…

2 confirmed