Arcbound Field · Field sheet · ABB · ABB-T184-COOL
ABB-T184-COOLCoolant flow low
ABB · Terra 184 · Liquid cooling
Safety
Qualified EVSE personnel only. Follow site LOTO and OEM HV / arc-flash boundaries. Depressurize coolant loops before opening quick-connects; capture spills. Not a substitute for OEM service manuals or AHJ requirements.
How it presents
- Display
- Coolant flow low
Symptom
Coolant flow low on abb (terra-184): ABB Terra HMI fault banner + service menu shows ABB-T184-COOL. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ABB Connected Services / OCPP StatusNotification info before opening the cabinet.
Root causes (by observed frequency)
- #1 Restricted airflow or coolant flow causing Coolant flow low
Filters, pump airlocks, and blocked inlets beat sensor swaps
- #2 Temp sensor open/short or harness damage at connector
- #3 Ambient / sun load plus aggressive OEM derate thresholds
Diagnostic procedure
1. Capture ABB Terra HMI fault banner + service menu message for ABB-T184-COOL, connector ID, and last successful session time
Expected: Exact display string + OCPP status/errorInfo if present
Tools: phone photos (scrubbed), CSMS
2. Pull ABB Connected Services / OCPP StatusNotification info; confirm whether Coolant flow low follows one gun, one cabinet, or the whole site
Expected: Fault correlates to one path
Tools: CSMS export, OEM cloud
3. On model terra-184 hardware, isolate power quality / protective devices before opening HV for ABB-T184-COOL
Expected: Voltage in band; no unexpected trips
Tools: DMM, IR gun, LOTO kit
4. Execute rank-1 cause check for “Coolant flow low”; swap known-good cable/gun or stall if available
Expected: Fault moves with cable or stays with cabinet
Tools: known-good cable, IR, OEM service menu
5. If unresolved, escalate with ABB-T184-COOL evidence pack (HMI photo, OCPP snippet, readings) — Terra dual-standard sites: verify which gun and which stack faulted
Tools: ticket template
The fix
Clear ABB-T184-COOL (Coolant flow low) by correcting the ranked cause on abb / terra-184, then run a full validation session.
Fan, pump, or coolant kit
Bleed procedure required after pump/skid work
Suspect module or controller indicated by rank-1 cause
OEM abb service channel; keep serial for RMA
ABB-T184-COOL
- LOTO and verify zero energy per abb HV procedure before any bus work
- Correct rank-1 cause for ABB-T184-COOL; do not shotgun-replace modules
- Clear fault latches in HMI/CSMS; confirm StatusNotification returns to Available/Preparing as appropriate
- Run validation: authorize → handshake → ≥5 minutes energy → clean stop; capture MeterValues
- Document firmware, part lots, and scrubbed HMI photos for confirmations
Field photos
Related entries
Related guides
Field confirmations (2) — subscribers only, one per account.
Missing a sibling fault? Request an entry