EVBox
Field hub — common codes, ownership boundaries, and links into the fault database.
EVBox — field brand hub
EVBox Livo AC chargers appear on workplace and fleet Level 2 sites, often with load-balancing groups. Ownership is the unit (RCD, cable lock, OCPP stack) plus site load-manager behavior — not a DC cabinet. Confirm LMS/group policy before calling the charger dead when MeterValues sit at 0 A.
When this OEM shows up
Expect nuisance RCD trips, cable lock stuck, OCPP disconnects, and load-balance commands that drive the stall to 0 A while the unit looks “online.” Unit owns RCD, lock actuator, and local controller. Site/ops owns load-balance setpoints and backhaul. Electrician owns PE and feeder.
How faults present
- Local UI/LEDs: RCD trip, lock error, fault.
- OCPP: disconnect / Faulted; or Available with MeterValues at 0 A under load balance. Faulted path: /guides/ocpp-faulted-triage. Zero-amp policy: /entries/protocol-load-01-dynamic-load-management-caps-to-0-a.
- Cloud / CSMS: group load-balance setpoints and reconnect history.
- Physical: ice/debris in lock, wet glands after wash-down, antenna/Ethernet after remodel.
Ranked failure patterns
-
RCD trip nuisance — Moisture, EV leakage, aging RCD; do not keep resetting without cause. Entry: /entries/evbox-evb-lv-rcd-rcd-trip-nuisance. PE: /entries/protocol-gnd-01-ground-continuity-fail-at-dispenser.
-
Load balance zero amps — Group budget / priority, not a dead contactor. Entry: /entries/evbox-evb-lv-load-load-balance-zero-amps.
-
Livo OCPP disconnect — Backhaul/TLS/identity. Entry: /entries/evbox-evb-lv-com-livo-ocpp-disconnect. Related: /entries/protocol-ocpp-f02-heartbeat-timeout-to-csms, /entries/protocol-net-c01-dns-resolution-failure-to-csms.
-
Cable lock stuck — Mechanical debris, actuator, ice. Entry: /entries/evbox-evb-lv-lock-cable-lock-stuck.
Logs / tools
CSMS load-balance logs, StatusNotification/Heartbeat, LED photos, RCD trip count, manual lock release per OEM, DMM on PE, known-good cable if lock allows.
Escalate when
- Electrician: Persistent RCD with measured leakage/PE issues; supply faults.
- Network/ops: OCPP identity/URL; load-balance policy starving stalls.
- OEM: Lock actuator or RCD hardware after site causes cleared.
Do not replace chargers for load-balance zero-amp events.
Field checklist
- Is MeterValues at 0 A while status stays Available? Check load-balance setpoints first.
- Photo local UI and note RCD trip count / lock state.
- Pull CSMS group load-balance log for the stall window.
- If RCD: dry, inspect glands/cable, measure PE — do not keep resetting.
- If OCPP disconnect: Heartbeat/DNS/TLS before board RMA.
- If lock stuck: debris/ice/manual release per OEM before actuator RMA.
- Confirm sibling Livo units in the same group still get amps.
A whole group starved of amps is ops policy, not ten dead contactors. Use /guides/ocpp-faulted-triage only when the stall is actually Faulted.
Models
Fault index (4)
EVB-LV-COMEVBox · Livo · AC Level 2 solo+Livo OCPP disconnect
EVBox Livo drops off the CSMS intermittently: Cloud shows Offline or repeated reconnects while the pedestal's local LEDs…
EVB-LV-RCDEVBox · Livo · AC Level 2 solo+RCD trip nuisance
EVBox Livo's residual current device opens on plug-in, during rain, or mid-session, then resets and holds briefly before…
EVB-LV-LOCKEVBox · Livo · AC Level 2 solo+Cable lock stuck
EVBox Livo's cable lock actuator either stays engaged after a session ends, trapping the connector in the vehicle, or fa…
EVB-LV-LOADEVBox · Livo · AC Level 2 solo+Load balance zero amps
EVBox Livo authorizes a session normally but delivers 0 A during peak periods, then resumes charging on its own once dem…