Flo
Field hub — common codes, ownership boundaries, and links into the fault database.
Flo — field brand hub
Flo Smart Two AC units show up on workplace and public Level 2 pads. Ownership is the pedestal: pilot path, meter, auth card, and enclosure thermal — plus Flo network auth. Split “won’t authorize” from “authorizes but no energy” before you open the enclosure.
When this OEM shows up
Typical tickets: auth card not accepted, meter error, pilot diode fail (no charge with EV plugged), overtemp enclosure in sun/poor airflow. Site owns PE and feeder; Flo/CPO owns credential mapping; the unit owns pilot, meter, and local thermal path.
How faults present
- Local LEDs / display: meter error, overtemp, fault.
- Flo network / OCPP: Authorize rejected vs Faulted mid-session. Auth-only: /guides/fleet-cms-triage, /entries/protocol-ocpp-f03-authorize-rejected-invalid-idtag. Hard Faulted: /guides/ocpp-faulted-triage.
- Cloud: card credential mapping and meter register history.
- Physical: hot enclosure in sun, blocked vents, damaged cable/pilot pins.
Ranked failure patterns
-
Auth card not accepted — Credential/list/reader; not a pilot fault. Entry: /entries/flo-flo-st-auth-auth-card-not-accepted. Related: /entries/protocol-rfid-01-rfid-reader-no-uid.
-
Smart Two meter error — Meter path / CRC-class issues affecting session close. Entry: /entries/flo-flo-st-met-smart-two-meter-error. Metering guide: /guides/metering-payment, /entries/protocol-met-01-energy-meter-crc-error.
-
Pilot diode fail — CP path; EV never reaches charge-ready. Entry: /entries/flo-flo-st-pilot-pilot-diode-fail.
-
Overtemp enclosure — Sun load, blocked vents, failed fan if equipped. Entry: /entries/flo-flo-st-temp-overtemp-enclosure.
Logs / tools
Flo portal event log, Authorize timeline, LED photos, IR on enclosure, DMM on CP, known-good credential card, PE continuity (/entries/protocol-gnd-01-ground-continuity-fail-at-dispenser).
Escalate when
- Electrician: Supply issues, enclosure heat from upstream overload, wiring on pilot, PE problems.
- Network/Flo ops: Card not in allow-list, site group mis-map.
- OEM: Meter board or pilot hardware after credential and wiring cleared.
Do not OEM-escalate auth rejects that are credential-only.
Field checklist
- Split the ticket: auth fail vs meter/pilot/thermal with auth OK.
- Photo LEDs/display and note ambient sun load on the enclosure.
- Pull Flo portal Authorize timeline and last good session.
- Try a known-good credential before opening the pilot path.
- If meter error: capture register/CRC evidence for /guides/metering-payment — do not treat as isolation.
- If no charge after authorize: CP/pilot check and second vehicle when available.
- Clear vents / shade path before condemning overtemp hardware.
Soft-offline with healthy local LEDs is backhaul/CSMS (/entries/protocol-ocpp-f02-heartbeat-timeout-to-csms), not a pilot diode.
Models
Fault index (4)
FLO-ST-METFlo · Smart Two · AC Level 2 solo+Smart Two meter error
Flo Smart Two reports a meter/measurement error mid-session or at start: the app or station LED shows a metering fault, …
FLO-ST-AUTHFlo · Smart Two · AC Level 2 solo+Auth card not accepted
Flo Smart Two rejects RFID card or app authorization with a 'card not accepted' message while the station otherwise show…
FLO-ST-TEMPFlo · Smart Two · AC Level 2 solo+Overtemp enclosure
Flo Smart Two derates or trips to Faulted with an overtemperature message during full-sun exposure or when enclosure ven…
FLO-ST-PILOTFlo · Smart Two · AC Level 2 solo+Pilot diode fail
Flo Smart Two fails the control-pilot handshake: the unit never leaves State A/B and the display or app shows a pilot/di…