LOAD-01Cross-brand / Protocol · Power cabinet / LMSFree sampleDynamic load management caps to 0 A
Dynamic load management caps to 0 A (LOAD-01) — Load management field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.
CFG-03Cross-brand / Protocol · DC Fast ChargersFree samplePower module map incorrect after expansion
Power module map incorrect after expansion (CFG-03) — Configuration field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.
CP-E250-PFCChargePoint · Express 250 · DC Fast ChargersEarly access pro+PFC stage overcurrent
ChargePoint PFC stage overcurrent (CP-E250-PFC) — confirm Express power cabinet vs dispenser ownership before parts. Fie…
ABB-T54-GRIDABB · Terra 54 · DC Fast Chargers solo+Grid undervoltage trip
Terra 54 grid undervoltage trip — utility/feeder sag coinciding with charge start. Field techs should correlate HMI/Clou…
TRI-PK-PWRTritium · PK350 · DC Fast ChargersEarly access pro+Rectifier stage fault
PK rectifier stage fault — early-access HV power stage; LOTO and OEM diagnostics. Field techs should correlate HMI/Cloud…
BTC-HP-PFCBTC Power · HP150 · DC Fast Chargers solo+Input PFC fault
BTC HP input PFC fault — grid/PFC stage under load; correlate site voltage. Field techs should correlate HMI/Cloud times…
KEM-SAT-DYNKempower · Satellite · DC Fast ChargersEarly access pro+Dynamic power allocation stuck
Kempower dynamic power pool fault — early-access pool assignment/module map issues. Field techs should correlate HMI/Clo…
CAB-BUSSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+DC bus undervoltage
DC bus undervoltage — bus collapses under load from grid/feed or module issues. site-generic field note: keep evidence s…
CAB-PARSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+Parallel cabinet sync fail
Parallel cabinet sync fail — paralleled cabinets refuse to share or sync DC bus. site-generic field note: keep evidence …
DEP-SEQSite stack (generic) · Power cabinet / LMS solo+Sequential start brownout
Sequential start brownout — too many stalls authorize together; voltage sag trips protection. site-generic field note: k…
ALP-HYC-GRIDAlpitronic · HYC300 · DC Fast Chargers solo+Grid overvoltage
Alpitronic Hypercharger trips on grid overvoltage, aborting active sessions and refusing new ones until the input voltag…
PE-NB-GRIDPower Electronics · NB 360 · DC Fast Chargers solo+Input phase loss
Power Electronics NB360 loses an input grid phase, faulting the cabinet in a way that can superficially resemble a modul…
SCH-EV-PHASESchneider Electric · EVlink · AC Level 2 solo+Missing phase on 3P install
Schneider EVlink on a three-phase install reports a missing or unbalanced phase after panel or breaker work: the unit ei…
BESS-UVFluence / BESS · BESSFree sampleBESS undervoltage at cabinet
Fluence BESS reports an undervoltage (UV) inhibit at the EVSE feed — either the PCS AC output or the shared DC bus — so dependent chargers brown out mid-session or latch Faulted while the BESS HMI independently alarms UV. It shows up most on hot afternoons when several dispensers ramp together and SOC is already drawn down from an overnight fleet pull, so the first minutes of triage are about proving whether the EVSE is really broken or the depot just asked for more than the BESS could deliver at that SOC.
BESS-OVFluence / BESS · BESS solo+BESS overvoltage trip
Fluence BESS overvoltage (OV) protection trips and opens the discharge/charge path feeding the EVSE bus, so dependent di…
SWG-PFEaton · Switchgear solo+Power factor / harmonic trip
Power factor or harmonic distortion protection trips, or the utility flags a power quality complaint, and the timing lin…