The EVSE Directory · Field sheet · ChargePoint · CP-E250-GF
CP-E250-GFFree sampleGround fault trip under rain
ChargePoint · Express 250 · DC Fast Chargers
Safety
Never bypass GF protection to keep the stall up.
How it presents
Symptom
Express 250 ground-fault trip under rain, wash-down, or wet holster — Cloud Faulted and local GF latch may refuse clear until the moisture path is proven dry. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-E250-GF.
Root causes (by observed frequency)
- #1 Moisture bridging GF sensing at dispenser holster, cable boot, or cabinet seam
Most common after storms or pressure washing
- #2 Damaged EV cable insulation or contaminated CCS pins holding a leakage path
- #3 Site PE / bonding high resistance causing nuisance trips under load
See GND-01 before condemning the GF board
- #4 Failed GF sensing module after repeated wet clears
Diagnostic procedure
1. Photograph HMI/Cloud GF string, note weather, and whether trip is at plug-in or mid-session
Expected: Exact fault + weather context
Tools: phone
2. LOTO feeder; dry holster, cable boots, and enclosure seams before any reset spam
Expected: No standing water; seals intact
Tools: rags, light
3. Verify PE continuity pedestal-to-panel before a single protective reset
Expected: Low-ohm PE path
Tools: DMM
4. Known-good cable/vehicle prove on the failing dispenser after dry
Expected: Holds ≥5 min charge
Tools: known-good cable
5. OEM GF path only if dry known-good still trips — do not defeat protection
Tools: ChargePoint
The fix
Dry and prove PE first; replace GF sensing only after a dry known-good path still trips.
GF sensing / cable boot kit
OEM ChargePoint only
- LOTO and verify zero energy before opening wet enclosures.
- Dry and reseal holster/cable path; replace damaged boots.
- Confirm PE continuity; correct site bonding if open or high.
- Single GF clear after cause removal; validate a full session.
- Escalate OEM GF sensing only with scrubbed dry-fail evidence.