Arcbound Field · Field sheet · Cross-brand / Protocol · CHA-H01
CHA-H01CHAdeMO CAN timeout
Cross-brand / Protocol · Cables & connectors
Safety
Qualified EVSE personnel only. Follow site LOTO and OEM HV / arc-flash boundaries. Not a substitute for OEM service manuals or AHJ requirements.
How it presents
- Display
- CHAdeMO CAN timeout
Symptom
CHAdeMO CAN timeout on protocol: CSMS StatusNotification + connector LEDs shows CHA-H01. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate OCPP websocket / SECC / vehicle logs as applicable before opening the cabinet.
Root causes (by observed frequency)
- #1 Connector, PE/PP/CP, or SECC stage failure for CHAdeMO CAN timeout
Prove cable + latch + vehicle before power-module blame
- #2 Adapter or vehicle profile quirk on this site’s connector map
- #3 SECC firmware / clock / discovery misconfig after update
Diagnostic procedure
1. Capture CSMS StatusNotification + connector LEDs message for CHA-H01, connector ID, and last successful session time
Expected: Exact display string + OCPP status/errorInfo if present
Tools: phone photos (scrubbed), CSMS
2. Pull OCPP websocket / SECC / vehicle logs as applicable; confirm whether CHAdeMO CAN timeout follows one gun, one cabinet, or the whole site
Expected: Fault correlates to one path
Tools: CSMS export, OEM cloud
3. On hardware, isolate power quality / protective devices before opening HV for CHA-H01
Expected: Voltage in band; no unexpected trips
Tools: DMM, IR gun, LOTO kit
4. Execute rank-1 cause check for “CHAdeMO CAN timeout”; swap known-good cable/gun or stall if available
Expected: Fault moves with cable or stays with cabinet
Tools: known-good cable, IR, OEM service menu
5. If unresolved, escalate with CHA-H01 evidence pack (HMI photo, OCPP snippet, readings) — Stay OEM-agnostic until the protocol stage pins a hardware path
Tools: ticket template
The fix
Clear CHA-H01 (CHAdeMO CAN timeout) by correcting the ranked cause on protocol, then run a full validation session.
DC cable / gun assembly
Match cooled vs uncooled; OEM-approved only
protocol-cable-std
Suspect module or controller indicated by rank-1 cause
OEM protocol service channel; keep serial for RMA
CHA-H01
- LOTO and verify zero energy per protocol HV procedure before any bus work
- Correct rank-1 cause for CHA-H01; do not shotgun-replace modules
- Clear fault latches in HMI/CSMS; confirm StatusNotification returns to Available/Preparing as appropriate
- Run validation: authorize → handshake → ≥5 minutes energy → clean stop; capture MeterValues
- Document firmware, part lots, and scrubbed HMI photos for confirmations
Related entries
Related guides
Field confirmations (2) — subscribers only, one per account.
Missing a sibling fault? Request an entry