BTC Power
Field hub — common codes, ownership boundaries, and links into the fault database.
BTC Power — field brand hub
BTC HP150-class cabinets show up on public and fleet pads with CCS and NACS paths. Tickets cluster around isolation, door/interlock bounce, OCPP reconnect storms after cellular drop, and PFC under sustained load. Most wasted truck rolls happen when a tech swaps PFC modules before checking cabinet↔dispenser CAN, door switch state, or backhaul.
When this OEM shows up / cabinet vs dispenser
HP150-class units are often an integrated service envelope, but ownership still splits in practice:
Dispenser / connector path: NACS adapter path fault, CCS handshake issues, local display messaging.
Cabinet power path: isolation trip, input PFC fault.
Interlock / enclosure: service door switch bounce — chatter that latches Faulted without a true power failure.
Link / network: OCPP reconnect storm; also prove cabinet↔dispenser CAN before PFC RMA (same lesson as other split architectures).
Apply the rule: one gun vs whole cabinet. Isolation after a cable swap is cable until proven otherwise. Photograph HMI string, connector ID, and door/switch state before you call it a power-module failure.
How faults typically present
Local display / LED bank
- BTC-HP-* codes on local display or LED bank.
- Door bounce: intermittent Faulted that clears when the door is reseated — do not call it isolation yet.
- Isolation trip: often at CableCheck / plug-in; mid-session trip needs MeterValues curve.
OCPP / CSMS
- Reconnect storms: Available → Offline → Faulted churn; Heartbeat gaps. Triage: /guides/ocpp-faulted-triage, /entries/protocol-ocpp-f02-heartbeat-timeout-to-csms, /entries/protocol-net-c01-dns-resolution-failure-to-csms.
- Isolation / PFC usually land as Faulted with GroundFailure / InternalError / vendor string — log
vendorErrorCodeverbatim. - NACS path: may fail Authorize/handshake while CCS on the sibling connector works — use /guides/nacs-field-notes.
Cloud / PLC event list
- BTC CSMS + cabinet PLC event list before wrenching. Correlate timestamps with modem drops vs door opens vs plug events.
Physical cues
- Door seals, water ingress, hot cable at high SOC ramp, debris in inlets, antenna connectors loose after service.
Ranked common failure patterns
-
HP150 isolation trip — Cable/gun IR or wet path before PFC condemnation. Entry: /entries/btc-power-btc-hp-iso-hp150-isolation-trip. Stage: /entries/protocol-ccs-h03-cable-check-isolation-fail, /guides/ccs-handshake-basics.
-
Service door switch bounce — Misaligned latch, worn switch, vibration. Reseat, adjust, replace switch before board hunts. Continuity on the loop with the door closed and latched. Entry: /entries/btc-power-btc-hp-door-service-door-switch-bounce.
-
OCPP reconnect storm — Cellular drop, NAT keepalive, wrong URL/identity after SIM/board swap. Entry: /entries/btc-power-btc-hp-ocpp-ocpp-reconnect-storm. Modem path: /entries/sierra-wireless-mdm-rssi-rssi-too-low-in-cabinet.
-
NACS adapter path fault — Adapter/latch/SECC/vehicle profile; prove with known-good path and CCS sibling if present. Entry: /entries/btc-power-btc-hp-nacs-nacs-adapter-path-fault. Related: /entries/protocol-nacs-h01-nacs-handshake-timeout-on-adapter-path, /entries/protocol-nacs-h03-nacs-thermal-derate-to-zero.
-
Input PFC fault — After grid/phase proven under load. Entry: /entries/btc-power-btc-hp-pfc-input-pfc-fault. PQ: /guides/site-power-quality-basics.
-
Handshake before current — Latch/SLAC/SDP failures with healthy DC bus: /entries/protocol-ccs-h01-ccs-slac-timeout, /entries/protocol-ccs-h02-sdp-failed-secc-not-responding, /entries/protocol-ccs-h04-precharge-voltage-mismatch.
-
Ground / PE outdoor — Rain and wash-down at glands/boots (/entries/protocol-gnd-01-ground-continuity-fail-at-dispenser).
-
Stuck Faulted after reboot — Software latch, not endless power cycles (/entries/protocol-ocpp-f01-statusnotification-stuck-faulted-after-reboot).
Log sources / tools
| Source | What you pull |
|---|---|
| Local display / LEDs | Live code, door/E-stop state |
| Cabinet PLC event list | Door, CAN, PFC, isolation timestamps |
| CSMS / OCPP | Reconnect timeline, StatusNotification, MeterValues |
| Modem stats | RSRP, APN, disconnect counters |
| Known-good cable / NACS path | Moves isolation or NACS fault |
| DMM / megger | PE, IR, input phases; interlock loop continuity |
Field checklist
- One gun or whole cabinet?
- Door/interlock state photographed?
- Weather / recent cable or modem work?
- OCPP StatusNotification snippet for the stall window
- Dry + known-good cable if ISO
- Feeder voltage under load if multi-stall pad
- CAN / link health before PFC module RMA
When to escalate
Electrician / site power — Phase loss / undervoltage matching PFC trips; PE issues on isolation tickets that fail megger at pedestal; breaker/feeder work.
Network / CSMS — Reconnect storms with modem/CSMS evidence; identity/URL after SIM work; auth-only failures with healthy energy path (/entries/protocol-ocpp-f03-authorize-rejected-invalid-idtag).
BTC OEM — PFC module after grid + CAN proven; isolation path confirmed cable-independent (stays with cabinet); door switch hardware after bounce documented and adjustment failed; NACS path after known-good adapter/vehicle proven.
Do not escalate door bounce or reconnect storms as PFC RMA. Do not swap modules for NACS adapter faults until the adapter/SECC path is proven. Payment-only: /entries/ingenico-pay-to-payment-terminal-timeout.
Public HP150 pads and depot installs share the same triage order: presentation → one-gun vs cabinet → cable/ISO → interlock → power → network. Write that order into the ticket so the next tech does not restart at module RMA.
Keep PE continuity and door-switch photos in every outdoor BTC ticket; wash-down and latch bounce are still the majority of “mystery Faulted” callbacks.
Keep PE continuity and door-switch photos in every outdoor BTC ticket; wash-down and latch bounce are still the majority of “mystery Faulted” callbacks.
Keep PE continuity and door-switch photos in every outdoor BTC ticket; wash-down and latch bounce are still the majority of “mystery Faulted” callbacks.
Models
Fault index (5)
BTC-HP-ISOBTC Power · HP150 · DC Fast ChargersFree sampleHP150 isolation trip
BTC HP150 isolation trip — cable/moisture/ISO path on HP family before power-module crates. Field techs should correlate HMI/Cloud timestamps with HP family often needs power-cabinet vs dispenser CAN check before module swap
BTC-HP-NACSBTC Power · HP150 · DC Fast Chargers solo+NACS adapter path fault
BTC HP NACS adapter path fault — adapter/port thermal or proximity before CCS stack blame. Field techs should correlate …
BTC-HP-DOORBTC Power · HP150 · DC Fast Chargers solo+Service door switch bounce
BTC HP service door switch bounce — interlock chatter after service; never jumper. Field techs should correlate HMI/Clou…
BTC-HP-PFCBTC Power · HP150 · DC Fast Chargers solo+Input PFC fault
BTC HP input PFC fault — grid/PFC stage under load; correlate site voltage. Field techs should correlate HMI/Cloud times…
BTC-HP-OCPPBTC Power · HP150 · DC Fast Chargers solo+OCPP reconnect storm
BTC HP OCPP reconnect storm — Soft-offline reconnect loops; backhaul/config before boards. Field techs should correlate …