Arcbound Field · Field sheet · BTC Power · BTC-HP-ISO
BTC-HP-ISOHP150 isolation trip
BTC Power · HP150 · DC Fast Chargers
Safety
Qualified EVSE personnel only. Follow site LOTO and OEM HV / arc-flash boundaries. Insulation and ground tests have their own hazards — use rated testers and OEM limits. Not a substitute for OEM service manuals or AHJ requirements.
How it presents
- Display
- HP150 isolation trip
- OCPP
- Faulted (StatusNotification) — capture errorCode/info
Symptom
HP150 isolation trip on btc-power (hp150): BTC Power local display / LED bank shows BTC-HP-ISO. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate BTC CSMS + cabinet PLC event list before opening the cabinet.
Root causes (by observed frequency)
- #1 Cable or gun insulation breakdown presenting as BTC-HP-ISO
Swap known-good cooled/uncooled cable before condemning power stage
- #2 Coolant contamination or leak wetting DC bus sensors
- #3 Y-cap / filter path degraded after surge or grid event
Diagnostic procedure
1. Capture BTC Power local display / LED bank message for BTC-HP-ISO, connector ID, and last successful session time
Expected: Exact display string + OCPP status/errorInfo if present
Tools: phone photos (scrubbed), CSMS
2. Pull BTC CSMS + cabinet PLC event list; confirm whether HP150 isolation trip follows one gun, one cabinet, or the whole site
Expected: Fault correlates to one path
Tools: CSMS export, OEM cloud
3. On model hp150 hardware, isolate power quality / protective devices before opening HV for BTC-HP-ISO
Expected: Voltage in band; no unexpected trips
Tools: DMM, IR gun, LOTO kit
4. Execute rank-1 cause check for “HP150 isolation trip”; swap known-good cable/gun or stall if available
Expected: Fault moves with cable or stays with cabinet
Tools: known-good cable, IR, OEM service menu
5. If unresolved, escalate with BTC-HP-ISO evidence pack (HMI photo, OCPP snippet, readings) — HP family often needs power-cabinet vs dispenser CAN check before module swap
Tools: ticket template
The fix
Clear BTC-HP-ISO (HP150 isolation trip) by correcting the ranked cause on btc-power / hp150, then run a full validation session.
Suspect module or controller indicated by rank-1 cause
OEM btc-power service channel; keep serial for RMA
BTC-HP-ISO
- LOTO and verify zero energy per btc-power HV procedure before any bus work
- Correct rank-1 cause for BTC-HP-ISO; do not shotgun-replace modules
- Clear fault latches in HMI/CSMS; confirm StatusNotification returns to Available/Preparing as appropriate
- Run validation: authorize → handshake → ≥5 minutes energy → clean stop; capture MeterValues
- Document firmware, part lots, and scrubbed HMI photos for confirmations