CCS-H11Cross-brand / Protocol · Cables & connectorsFree sample

EVSideCableCheck unknown error

EVSideCableCheck unknown error (CCS-H11) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
CP-E250-ISOChargePoint · Express 250 · DC Fast ChargersFree sample

Isolation fault after cable swap

Express 250 isolation fault before or during CableCheck after a cable swap, rain, or cooled-cable service — one gun or whole power cabinet. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-E250-ISO.

1 confirmed
ALP-HYC-ISOAlpitronic · HYC300 · DC Fast ChargersFree sample

HYC isolation fault

Alpitronic Hypercharger fails isolation during CableCheck on one connector, or occasionally across the whole cabinet, most often after rain, a cable swap, or overnight condensation. Because HYC300 modules share a common coolant loop, a wet or contaminated path on one gun can occasionally present as a broader isolation issue across the bank.

2 confirmed
DEL-UFC-GFDelta · UFC100 · DC Fast ChargersFree sample

UFC ground fault

Delta UFC100 dispenser trips ground fault mid-session or during CableCheck, most often after rain, wash-down, or a recent cable service call. HMI banner reads Ground Fault while OCPP reports Faulted/GroundFailure; the fault can lock a single gun or take the whole cabinet Unavailable if the sensing sits upstream of the split.

2 confirmed
AUT-MC-ISOAutel · MaxiCharger DC · DC Fast ChargersFree sample

MaxiCharger isolation

Autel MaxiCharger DC fails isolation/CableCheck on one connector while the peer port on the same dual-standard unit stays healthy. Because MaxiCharger DC often pairs a CCS and NACS port from a shared cabinet, techs must confirm which physical port and which cable actually failed before assuming a cabinet-wide isolation fault.

3 confirmed
PE-NB-ISOPower Electronics · NB 360 · DC Fast ChargersFree sample

NB360 isolation

Power Electronics NB360 fails isolation during CableCheck, and because the NB360 cabinet uses a multi-module current-share architecture, technicians must confirm whether the fault traces to a single module's contribution or the shared measurement path before opening the whole cabinet. Cable moisture and single-module contamination are the two leading field causes.

2 confirmed