Power Electronics · NB 360 · DC Fast Chargers
Safety
LOTO for all HV module work. Avoid replacing multiple modules speculatively — isolate to the specific contributor first.
How it presents
Symptom
Power Electronics NB360 fails isolation during CableCheck, and because the NB360 cabinet uses a multi-module current-share architecture, technicians must confirm whether the fault traces to a single module's contribution or the shared measurement path before opening the whole cabinet. Cable moisture and single-module contamination are the two leading field causes.
Root causes (by observed frequency)
- #1 Cable insulation breakdown or moisture on the failing connector path
Prove with a known-good cable dry-swap before touching any module.
- #2 A single power module's isolation contribution dragging down the overall cabinet reading
NB360's multi-module architecture means one contaminated or wet module can fail isolation for the whole bank even if the others are clean.
- #3 ISO measurement hardware fault on the shared measurement path
Pursue only after cable and individual module checks are clean.
- #4 Coolant or condensation ingress at a module quick-connect after service
Check module service history if the fault started shortly after a repair visit.
Diagnostic procedure
1. Classify whether the fault names a single connector, a single module, or the whole cabinet in the service UI.
Expected: Fault attributed to a specific connector or module rather than being cabinet-wide by default
Tools: PE service UI
2. Swap in a known-good cable on the failing connector and retest dry.
Expected: Fault clears with a dry, known-good cable if the original cable caused it
Tools: known-good cable
3. Identify which individual module is contributing to the isolation fault using the service menu's per-module readings.
Expected: One module shows an out-of-spec isolation contribution while others read normal
Tools: PE service tool
4. Inspect the identified module's quick-connects and enclosure for moisture or coolant residue.
Expected: No visible moisture or coolant contamination at the module interface
Tools: flashlight, IR camera
5. Escalate to Power Electronics OEM's module isolation service path if cable and module inspection are both clean.
Expected: OEM confirms and repairs the specific module or shared measurement fault
Tools: PE OEM support
The fix
Cable first, then isolate to a single module before swapping the entire bank.
Cable/gun
Match connector spec
Power module
PE OEM part, ordered per identified module
- Prove the cable with a known-good, dry swap before assuming any module or the shared measurement path is at fault, since cable moisture remains the single most common cause.
- Use the service menu's per-module isolation readings to identify exactly which module, if any, is dragging down the cabinet-wide measurement rather than replacing multiple modules speculatively.
- Inspect the identified module's quick-connects for moisture or coolant contamination, since this is a known cause of single-module isolation faults on NB360's shared architecture.
- Replace only the specific faulted module through Power Electronics' OEM channel once cable and contamination are ruled out, then validate with a full CableCheck and session before returning the bank to service.