CCS-H03Cross-brand / Protocol · Cables & connectorsFree sample

Cable check isolation fail

Cable check isolation fail (CCS-H03) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
GND-02Cross-brand / Protocol · DC Fast ChargersFree sample

Isolation monitor nuisance trip wet weather

Isolation monitor nuisance trip wet weather (GND-02) — Ground / isolation field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CP-E250-ISOChargePoint · Express 250 · DC Fast ChargersFree sample

Isolation fault after cable swap

Express 250 isolation fault before or during CableCheck after a cable swap, rain, or cooled-cable service — one gun or whole power cabinet. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-E250-ISO.

1 confirmed
ABB-T54-ISOABB · Terra 54 · DC Fast ChargersFree sample

Isolation error before charge

Terra 54 isolation error before charge — rain/cable/ISO path before power module blame. Field techs should correlate HMI/Cloud timestamps with Verify which gun and which stack faulted on dual-standard Terra sites.

2 confirmed
TRI-PK-ISOTritium · PK350 · DC Fast ChargersFree sample

PK350 isolation fault

PK350 isolation fault — cooled-cable/moisture path; PK liquid-cooled rules differ from RTM air-cooled. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.

1 confirmed
BTC-HP-ISOBTC Power · HP150 · DC Fast ChargersFree sample

HP150 isolation trip

BTC HP150 isolation trip — cable/moisture/ISO path on HP family before power-module crates. Field techs should correlate HMI/Cloud timestamps with HP family often needs power-cabinet vs dispenser CAN check before module swap

1 confirmed
ALP-HYC-ISOAlpitronic · HYC300 · DC Fast ChargersFree sample

HYC isolation fault

Alpitronic Hypercharger fails isolation during CableCheck on one connector, or occasionally across the whole cabinet, most often after rain, a cable swap, or overnight condensation. Because HYC300 modules share a common coolant loop, a wet or contaminated path on one gun can occasionally present as a broader isolation issue across the bank.

2 confirmed
AUT-MC-ISOAutel · MaxiCharger DC · DC Fast ChargersFree sample

MaxiCharger isolation

Autel MaxiCharger DC fails isolation/CableCheck on one connector while the peer port on the same dual-standard unit stays healthy. Because MaxiCharger DC often pairs a CCS and NACS port from a shared cabinet, techs must confirm which physical port and which cable actually failed before assuming a cabinet-wide isolation fault.

3 confirmed
SIE-SD-ISOSiemens · Sicharge D · DC Fast ChargersFree sample

Sicharge isolation

Siemens Sicharge D reports an isolation fault on one connector path while the peer gun on the same cabinet may remain Available, and technicians must confirm whether the power cabinet or the dispenser head owns the failing measurement before opening either enclosure. Weather exposure and recent cable service are the most common triggers.

1 confirmed
PE-NB-ISOPower Electronics · NB 360 · DC Fast ChargersFree sample

NB360 isolation

Power Electronics NB360 fails isolation during CableCheck, and because the NB360 cabinet uses a multi-module current-share architecture, technicians must confirm whether the fault traces to a single module's contribution or the shared measurement path before opening the whole cabinet. Cable moisture and single-module contamination are the two leading field causes.

2 confirmed