The EVSE Directory · Field sheet · Cross-brand / Protocol · OCPP-F05
OCPP-F05Free sampleMeterValues missing during session
Cross-brand / Protocol · DC Fast Chargers
Safety
Meter work may be behind LOTO covers — follow OEM.
How it presents
Symptom
MeterValues missing during session — energy runs locally but CSMS billing/telemetry shows gaps or zero MeterValues. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on OCPP-F05.
Root causes (by observed frequency)
- #1 MeterValues sample interval misconfigured or disabled
Config before hardware
- #2 Meter/register communication loss inside the cabinet
- #3 CSMS rejecting MeterValues (clock/format)
- #4 Websocket congestion dropping measurands under load
Diagnostic procedure
1. Check GetConfiguration for MeterValue sample intervals
Expected: Non-zero sensible interval
Tools: CSMS
2. Compare local session kWh vs CSMS MeterValues
Expected: Gap vs match
Tools: HMI/CSMS
3. Inspect meter comms/alarms on OEM service menu
Expected: Meter online
Tools: OEM tool
4. Verify clock skew not invalidating measurands
Expected: Time OK
Tools: HMI
5. Repair meter harness or OEM meter only after config proven
Tools: OEM
The fix
Missing MeterValues is config/meter-comms/CSMS accept — prove before energy-meter RMA.
- Restore MeterValues configuration before replacing meters.
- Fix cabinet meter communications if the OEM menu shows loss.
- Correct clock/format issues rejected by CSMS. Document readings and scrubbed photos for OCPP-F05 before closing the ticket.
- Stabilize backhaul if drops only appear under multi-stall load.
- Validate a session with continuous MeterValues in CSMS.