The EVSE Directory · Field sheet · Cross-brand / Protocol · OCPP-F07
OCPP-F07Free sampleConnector becomes Unavailable after SuspendEV
Cross-brand / Protocol · DC Fast Chargers
Safety
Mind pinch points on latches.
How it presents
Symptom
Connector becomes Unavailable after SuspendEV — vehicle paused, then charger never returns to Available for the next driver. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on OCPP-F07.
Root causes (by observed frequency)
- #1 Missing StatusNotification transition after SuspendEVSE/EV
State machine stuck
- #2 Cable still detected / latch held after session end
- #3 CSMS never sending remote unlock/availability restore
- #4 OEM bug requiring connector reset procedure
Diagnostic procedure
1. Capture StatusNotification sequence around SuspendEV
Expected: Missing Available
Tools: CSMS
2. Check latch/cable detect physically after unplug
Expected: Cable free, latch open
Tools: hands
3. Try UnlockConnector / ChangeAvailability from CSMS
Expected: Available
Tools: CSMS
4. Local OEM reset of connector state if documented
Expected: Returns Available
Tools: HMI
5. Escalate with sequence log if reproducible every SuspendEV
Tools: OEM
The fix
Unavailable-after-SuspendEV is state/latch/CSMS restore — clear cable detect before reboots.
- Confirm the cable truly released before protocol resets.
- Use UnlockConnector/ChangeAvailability rather than hard reboot first.
- Apply OEM connector state reset if SuspendEV repeatedly sticks.
- File OEM ticket with the StatusNotification timeline. Document readings and scrubbed photos for OCPP-F07 before closing the ticket.
- Validate a suspend → unplug → next-driver start cycle. Document readings and scrubbed photos for OCPP-F07 before closing the ticket.