The EVSE Directory · Field sheet · Cross-brand / Protocol · OCPP-F13
OCPP-F13Free sampleChangeAvailability rejected while charging
Cross-brand / Protocol · DC Fast Chargers
Safety
Do not yank cables to force Inoperative.
How it presents
Symptom
ChangeAvailability rejected while charging — ops tries to set Inoperative mid-session and charger correctly rejects, or rejects even when idle due to state desync. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on OCPP-F13.
Root causes (by observed frequency)
- #1 CSMS sending ChangeAvailability during Active/Charging
Expected reject
- #2 Charger state machine thinks still Charging after stop
- #3 Wrong connectorId targeted
- #4 OEM requiring local finish before Inoperative
Diagnostic procedure
1. Check connector status at reject time
Expected: Charging vs Available
Tools: CSMS
2. Stop session cleanly; retry ChangeAvailability
Expected: Accepted when idle
Tools: CSMS
3. Verify connectorId in the ChangeAvailability call
Expected: Correct gun
Tools: CSMS
4. If idle but still rejecting, capture status machine and OEM reset
Tools: OEM
5. Train ops not to force Inoperative mid-charge without Stop
Tools: runbook
The fix
Most ChangeAvailability rejects are state/timing — stop first, then mark Inoperative.
- Stop the transaction before setting Inoperative. Document readings and scrubbed photos for OCPP-F13 before closing the ticket.
- Target the correct connectorId. Document readings and scrubbed photos for OCPP-F13 before closing the ticket.
- Clear stuck Charging state with OEM procedure if needed.
- Update ops runbooks to avoid mid-session availability fights.
- Confirm Accepted ChangeAvailability and physical unavailability.