The EVSE Directory · Field sheet · Siemens · SIE-SD-ISO
SIE-SD-ISOFree sampleSicharge isolation
Siemens · Sicharge D · DC Fast Chargers
Safety
LOTO required for any power cabinet access. Do not repeatedly clear an isolation fault without addressing the underlying cause.
How it presents
Symptom
Siemens Sicharge D reports an isolation fault on one connector path while the peer gun on the same cabinet may remain Available, and technicians must confirm whether the power cabinet or the dispenser head owns the failing measurement before opening either enclosure. Weather exposure and recent cable service are the most common triggers.
Root causes (by observed frequency)
- #1 Cable or gun insulation breakdown, often moisture-related, on the failing connector
Confirm with a known-good cable dry-swap before any cabinet-level troubleshooting.
- #2 Power-cabinet vs. dispenser path ownership misread, where techs troubleshoot the wrong physical enclosure
Sicharge D splits power electronics and dispenser head — confirm which side actually owns the ISO measurement for this fault code.
- #3 Contactor or bus contamination inside the power cabinet after a service event
Check for dust, condensation, or residue near the DC bus if the cable proves clean.
- #4 ISO measurement hardware fault within the power cabinet
Pursue only after cable and cabinet cleanliness are both confirmed.
Diagnostic procedure
1. Determine whether the fault is confined to one gun or affects the whole cabinet, and photograph the connector ID and HMI message.
Expected: Fault clearly attributed to one connector unless cabinet-wide
Tools: phone camera, HMI
2. Swap in a known-good cable on the failing connector and retest dry.
Expected: Fault clears with a known-good, dry cable if the original cable was the cause
Tools: known-good cable
3. Confirm which physical enclosure — power cabinet or dispenser — owns the ISO measurement for this specific fault code per Siemens documentation.
Expected: Fault ownership matches one specific enclosure, guiding where to open next
Tools: Siemens service documentation
4. Inspect the DC bus and contactor area inside the power cabinet for dust, condensation, or contamination.
Expected: Bus and contactor area clean and dry
Tools: flashlight, IR camera, LOTO
5. Escalate to Siemens OEM's isolation service procedure if cable and cabinet inspection both come back clean.
Expected: OEM confirms and repairs a hardware-level ISO fault
Tools: Siemens OEM support
The fix
Cable first, then confirm enclosure ownership before opening the Sicharge power cabinet.
Cable/gun
Match connector standard and cooled-cable spec
ISO measurement components
Siemens OEM part, cabinet-specific
- Dry the connector and prove the cable with a known-good swap before opening any enclosure, since cable-related moisture explains the majority of Sicharge D isolation faults.
- Confirm from Siemens documentation which enclosure — power cabinet or dispenser head — actually owns the isolation measurement circuit for this fault code before deciding where to open covers.
- Lock out and tag out the power cabinet if internal inspection is required, and check the DC bus and contactor area for contamination before replacing any ISO hardware.
- Run the Siemens OEM isolation service procedure only after cable and cabinet cleanliness are both confirmed, then validate with a full session of at least five minutes before closing the ticket.