Tritium field work splits hard between PK350 (liquid-cooled ultra-fast) and RTM75 (air-cooled mid-power). Sites often mix them under one CPO; treat cooling architecture as a first-class branch in every ticket. Isolation, cable-leak, and thermal paths are not interchangeable — name the platform before you pull a rectifier.
When this OEM shows up / cabinet vs dispenser
PK350 deployments typically present as a power/rectifier section + dispenser UI with liquid-cooled cables. Isolation and leak-detect faults often track the cable assembly or quick-connects, not the whole power stage. RTM75 is air-cooled — fan path, inlet filters, and GF under weather dominate; do not apply PK350 bleed procedures to RTM.
Dispenser / UI ownership: no-boot HMI, auth timeouts / empty local list, cellular failover flapping.
Power / rectifier ownership: rectifier stage fault, isolation (PK), ground fault (RTM).
Cable / thermal ownership: liquid-cooled cable leak detect (PK), gun temperature derate (PK), inlet fan blocked (RTM).
Internal link: RTM internal CAN bus error — prove harness/termination before power-stage RMA.
If one dispenser faults and the peer stays Available, chase cable/gun/ISO first. If the whole unit Faulted with cooling codes, stay in the CDU / cabinet cooling path. Ultra-fast sites also expose feeder limits when multiple PK units ramp together — measure power before condemning modules. Dispenser UI dark with cellular flapping is a backhaul/UI ticket until proven otherwise.
How faults typically present
HMI / service LEDs
- PK dispenser UI: fault strings / service LEDs (TRI-PK-*).
- RTM: service LED / local codes (TRI-RTM-*).
- UI no-boot: blank or looping screen while power section may still be alive — check supply and link before HV.
OCPP / Veefil / CSMS
- Faulted / Unavailable with Tritium vendor codes in
info. - Cellular failover flapping: Heartbeat gaps, reconnect storms — use /guides/ocpp-faulted-triage.
- Auth timeout with empty local list: offline auth policy / CSMS sync, not a gun fault (/guides/fleet-cms-triage).
- Soft derate long before hard Faulted on thermal paths — pull MeterValues curve.
Physical cues
- Glycol smell, puddles at holster, hot cable near handle on PK350; blocked RTM inlets after storms; water at glands on outdoor RTM.
Ranked common failure patterns
PK350
-
Isolation fault — Cable/gun IR or wet path before rectifier condemnation. Prove with known-good cooled cable. Entry: /entries/tritium-tri-pk-iso-pk350-isolation-fault. CableCheck stage: /entries/protocol-ccs-h03-cable-check-isolation-fail, /guides/ccs-handshake-basics.
-
Liquid-cooled cable leak detect — Quick-connects, jacket damage, residual after swap. Stop sessions; do not “top off and ignore.” Entry: /entries/tritium-tri-pk-cable-liquid-cooled-cable-leak-detect. Loop procedure: /guides/liquid-cooling-loops. Follow OEM fill/bleed after any cable swap — airlocks fake flow faults (/entries/site-generic-cool-air-airlocked-loop-after-fill).
-
Dispenser UI no boot — Supply, board, or link; prove backhaul/power to UI. Entry: /entries/tritium-tri-pk-disp-dispenser-ui-no-boot.
-
Cellular failover flapping — SIM/APN/antenna/RSSI in metal cabinets; RSSI OK ≠ stable websocket. Entry: /entries/tritium-tri-pk-net-cellular-failover-flapping. Heartbeat path: /entries/protocol-ocpp-f02-heartbeat-timeout-to-csms, /entries/protocol-net-c01-dns-resolution-failure-to-csms, /entries/sierra-wireless-mdm-rssi-rssi-too-low-in-cabinet.
-
Gun temperature derate — Coolant flow, sensor, sun load, repeated high-power sessions. Entry: /entries/tritium-tri-pk-gun-gun-temperature-derate.
-
Rectifier stage fault — After isolation, cooling, and grid proven. Entry: /entries/tritium-tri-pk-pwr-rectifier-stage-fault. Grid check: /guides/site-power-quality-basics.
RTM75
-
Ground fault — Rain, wash-down, boot seals, or true PE open. Entry: /entries/tritium-tri-rtm-gf-rtm-ground-fault. PE: /entries/protocol-gnd-01-ground-continuity-fail-at-dispenser.
-
Inlet fan blocked — Filters/debris; clear inlet before sensor swaps. Entry: /entries/tritium-tri-rtm-fan-inlet-fan-blocked.
-
Auth timeout — local list empty — Offline list / CSMS sync after network outage. Entry: /entries/tritium-tri-rtm-auth-auth-timeout-local-list-empty. Related: /entries/protocol-ocpp-f03-authorize-rejected-invalid-idtag.
-
Internal CAN bus error — Harness, termination, moisture at connectors. Entry: /entries/tritium-tri-rtm-can-internal-can-bus-error.
Cross-platform
- Handshake / latch before current with healthy power stage: /entries/protocol-ccs-h01-ccs-slac-timeout, /entries/protocol-ccs-h02-sdp-failed-secc-not-responding, /entries/protocol-ccs-h04-precharge-voltage-mismatch.
- Stuck Faulted after reboot: /entries/protocol-ocpp-f01-statusnotification-stuck-faulted-after-reboot.
- LMS caps that look like hardware failure: /entries/protocol-load-01-dynamic-load-management-caps-to-0-a.
Log sources / tools
| Source | What you pull |
|---|---|
| Dispenser UI / service LEDs | Live code, boot state |
| Tritium Veefil / CSMS | Event log, FW, SIM/modem stats |
| OCPP export | Heartbeat gaps, StatusNotification, Authorize, MeterValues |
| Coolant tools (PK) | Level, pressure/flow, leak dye/visual |
| IR / DMM / megger | Gun heat, PE, IR, phase |
| Known-good cooled cable (PK) | Leak/iso moves with cable |
For cellular tickets: RSRP/RSRQ, APN, antenna connector seating, and whether Ethernet failover exists. Never run a coolant pump dry to “test.” Photos of leak residue and holster seals (scrub PII).
Field checklist (first 15 minutes)
- PK350 or RTM75? (cooling branch)
- One gun or whole unit?
- Leak smell/puddle? If yes, stop and contain — do not keep testing.
- Recent cable/coolant work?
- OCPP snippet for the fault window
- Known-good cable swap if ISO/CCS and dry enough
- Feeder voltage under simultaneous ramp if multi-unit site
When to escalate
Electrician / site power — True PE open or feeder events correlating with GF / rectifier trips; supply issues to dispenser UI (separate from rectifier HV); utility/transformer limits under multi-PK ramp.
Network / CSMS ops — Failover flapping with modem stats pointing at APN/SIM/DNS/TLS; empty local auth list after prolonged offline — policy/sync, not hardware; wrong OCPP identity after board/SIM swap.
Tritium OEM — Rectifier stage with isolation + cooling + grid cleared; confirmed cooled-cable leak path needing OEM cable/RMA; UI board no-boot after supply and link proven; internal CAN after harness/termination documented; persistent cooling after bleed + filter + leak-free loop.
Do not escalate UI no-boot or cellular flap as a rectifier fault. Do not treat RTM GF like PK cable-leak coolant procedure. Payment-only failures belong to the billing stack (/entries/ingenico-pay-to-payment-terminal-timeout).
Models
Fault index (10)
TRI-PK-ISOTritium · PK350 · DC Fast ChargersFree samplePK350 isolation fault
PK350 isolation fault — cooled-cable/moisture path; PK liquid-cooled rules differ from RTM air-cooled. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.
TRI-PK-CABLETritium · PK350 · Liquid coolingFree sampleLiquid-cooled cable leak detect
PK350 liquid-cooled cable leak detect — contain spill, reseal/replace path, bleed before return to service. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.
TRI-PK-DISPTritium · PK350 · DC Fast Chargers solo+Dispenser UI no boot
PK dispenser UI no boot — HMI/SBC path while power cabinet may still be alive. Field techs should correlate HMI/Cloud ti…
TRI-PK-PWRTritium · PK350 · DC Fast ChargersEarly access pro+Rectifier stage fault
PK rectifier stage fault — early-access HV power stage; LOTO and OEM diagnostics. Field techs should correlate HMI/Cloud…
TRI-PK-NETTritium · PK350 · DC Fast ChargersEarly access pro+Cellular failover flapping
PK cellular failover flapping — early-access modem/SIM/DNS path before board RMA. Field techs should correlate HMI/Cloud…
TRI-PK-GUNTritium · PK350 · DC Fast Chargers solo+Gun temperature derate
PK gun temperature derate — handle/contact heat or sensor; sun and damaged guns rank high. Field techs should correlate …
TRI-RTM-GFTritium · RTM75 · DC Fast ChargersFree sampleRTM ground fault
RTM ground fault — air-cooled RTM: moisture/cable/PE; do not bleed coolant on RTM air path. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.
TRI-RTM-FANTritium · RTM75 · DC Fast Chargers solo+Inlet fan blocked
RTM inlet fan blocked — thermal path on air-cooled RTM; clean inlet before sensor swaps. Field techs should correlate HM…
TRI-RTM-AUTHTritium · RTM75 · DC Fast Chargers solo+Auth timeout local list empty
RTM auth timeout local list empty — offline auth cache/CSMS list, not power electronics. Field techs should correlate HM…
TRI-RTM-CANTritium · RTM75 · DC Fast ChargersEarly access pro+Internal CAN bus error
RTM internal CAN bus error — early-access internal comms; reseat/OEM. Field techs should correlate HMI/Cloud timestamps …