The EVSE DirectorySubscribe

Fault database

Search by code, symptom, brand, category, or connector. Full procedures gated by subscription — look for green Free sample badges for open procedures.

Viewing as free

74 results for “OCPP” · page 2 of 2

CFG-01Cross-brand / Protocol · DC Fast ChargersFree sample

Wrong OCPP URL after board swap

Wrong OCPP URL after board swap — new controller still points at lab/staging or old CSMS, so production Cloud never sees the charger. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on CFG-01.

3 confirmed
CFG-02Cross-brand / Protocol · DC Fast ChargersFree sample

Connector ID mismatch dual-gun cabinet

Connector ID mismatch dual-gun cabinet (CFG-02) — Configuration field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CFG-03Cross-brand / Protocol · DC Fast ChargersFree sample

Power module map incorrect after expansion

Power module map incorrect after expansion (CFG-03) — Configuration field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
VEH-X01Cross-brand / Protocol · Cables & connectors solo+

Known vehicle profile needs CCS pause workaround

Known vehicle profile needs CCS pause workaround (VEH-X01) — Vehicle profile field fault. Stay OEM-agnostic until the pr…

1 confirmed
VEH-X02Cross-brand / Protocol · Cables & connectors solo+

Legacy CHAdeMO only vehicles on CCS site

Legacy CHAdeMO only vehicles on CCS site (VEH-X02) — Vehicle profile field fault. Stay OEM-agnostic until the protocol s…

2 confirmed
VEH-X03Cross-brand / Protocol · Cables & connectors solo+

NACS native vehicle on CCS1-only dispenser

NACS native vehicle on CCS1-only dispenser (VEH-X03) — Vehicle profile field fault. Stay OEM-agnostic until the protocol…

3 confirmed
OCPP-F11Cross-brand / Protocol · DC Fast ChargersFree sample

StopTransaction id mismatch

StopTransaction id mismatch — stop fails or CSMS alarms because transactionId/idTag does not match the open transaction. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on OCPP-F11.

1 confirmed
OCPP-F12Cross-brand / Protocol · DC Fast ChargersFree sample

GetConfiguration key unknown storm

GetConfiguration key unknown storm — CSMS polls unsupported keys, filling logs and sometimes slowing the charger’s OCPP task. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on OCPP-F12.

1 confirmed
CCS-H10Cross-brand / Protocol · Cables & connectorsFree sample

SessionSetup ResponseCode Failed

SessionSetup ResponseCode Failed (CCS-H10) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
NACS-H04Cross-brand / Protocol · Cables & connectorsFree sample

NACS PP open mid-session

NACS PP open mid-session (NACS-H04) — NACS path field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
ISO-H04Cross-brand / Protocol · Cables & connectors solo+

CertificateInstallation rejected

CertificateInstallation rejected (ISO-H04) — ISO 15118 / PnC field fault. Stay OEM-agnostic until the protocol stage pin…

3 confirmed
CHA-H04Cross-brand / Protocol · Cables & connectors solo+

CHAdeMO available current zero

CHAdeMO available current zero (CHA-H04) — CHAdeMO field fault. Stay OEM-agnostic until the protocol stage pins a hardwa…

1 confirmed
NET-C05Cross-brand / Protocol · DC Fast ChargersFree sample

MTU black hole on cellular path

MTU black hole on cellular path — large OCPP frames fail while tiny pings seem fine; Boot/FW/MeterValues flake on LTE. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on NET-C05.

3 confirmed
LOAD-03Cross-brand / Protocol · Power cabinet / LMS solo+

LMS priority starves fleet overnight

LMS priority starves fleet overnight (LOAD-03) — Load management field fault. Stay OEM-agnostic until the protocol stage…

2 confirmed
GND-03Cross-brand / Protocol · DC Fast Chargers solo+

Bond jumper missing at pedestal

Bond jumper missing at pedestal (GND-03) — Ground / isolation field fault. Stay OEM-agnostic until the protocol stage pi…

2 confirmed
RFID-03Cross-brand / Protocol · DC Fast Chargers solo+

Local list full — new cards fail

Local list full — new cards fail (RFID-03) — RFID / auth field fault. Stay OEM-agnostic until the protocol stage pins a …

3 confirmed
CFG-04Cross-brand / Protocol · DC Fast ChargersFree sample

Wrong timezone breaks TOU LMS

Wrong timezone breaks TOU LMS (CFG-04) — Configuration field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
MET-03Cross-brand / Protocol · DC Fast Chargers solo+

kWh under-report vs utility CT

kWh under-report vs utility CT (MET-03) — Metering field fault. Stay OEM-agnostic until the protocol stage pins a hardwa…

3 confirmed
TEMP-03Cross-brand / Protocol · DC Fast Chargers solo+

Sun load derate on unshaded cabinet

Sun load derate on unshaded cabinet (TEMP-03) — Thermal / ambient field fault. Stay OEM-agnostic until the protocol stag…

3 confirmed
OCPP-F13Cross-brand / Protocol · DC Fast ChargersFree sample

ChangeAvailability rejected while charging

ChangeAvailability rejected while charging — ops tries to set Inoperative mid-session and charger correctly rejects, or rejects even when idle due to state desync. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on OCPP-F13.

2 confirmed
CCS-H11Cross-brand / Protocol · Cables & connectorsFree sample

EVSideCableCheck unknown error

EVSideCableCheck unknown error (CCS-H11) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
NET-C06Cross-brand / Protocol · DC Fast ChargersFree sample

CSMS rate-limits StatusNotification

CSMS rate-limits StatusNotification — after a reconnect storm the CSMS throttles, chargers appear offline/Faulted in UI despite healthy hardware. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on NET-C06.

1 confirmed
ABB-T184-COMABB · Terra 184 · DC Fast Chargers solo+

OCPP disconnect after peak

Terra 184 OCPP disconnect after peak — Soft-offline under load/heat, prove backhaul vs controller. Field techs should co…

2 confirmed
BTC-HP-OCPPBTC Power · HP150 · DC Fast Chargers solo+

OCPP reconnect storm

BTC HP OCPP reconnect storm — Soft-offline reconnect loops; backhaul/config before boards. Field techs should correlate …

1 confirmed
MDM-ANTSierra Wireless / Semtech · AirLink modem · Modem / cellular solo+

Antenna connector loose

Antenna connector loose — intermittent RSSI/OCPP with physical RF path broken. Field techs should correlate HMI/Cloud ti…

1 confirmed
MDM-FWSierra Wireless / Semtech · AirLink modem · Modem / cellular solo+

Modem FW bricks OCPP path

Modem FW bricks OCPP path — modem online to carrier but OCPP stack broken after FW. Field techs should correlate HMI/Clo…

1 confirmed
DEL-UFC-GFDelta · UFC100 · DC Fast ChargersFree sample

UFC ground fault

Delta UFC100 dispenser trips ground fault mid-session or during CableCheck, most often after rain, wash-down, or a recent cable service call. HMI banner reads Ground Fault while OCPP reports Faulted/GroundFailure; the fault can lock a single gun or take the whole cabinet Unavailable if the sensing sits upstream of the split.

2 confirmed
DEL-UFC-LOCKDelta · UFC100 · DC Fast Chargers solo+

Connector lock motor fail

Delta UFC100 connector lock motor fails to latch or release the CCS handle, leaving a session unable to start or a cable…

1 confirmed
AUT-MC-APPAutel · MaxiCharger DC · DC Fast Chargers solo+

App start fails OCPP ok

Autel MaxiCharger DC app-initiated sessions fail to start while OCPP Heartbeat continues normally to the CSMS, meaning t…

2 confirmed
SIE-SD-HMISiemens · Sicharge D · DC Fast Chargers solo+

Touch HMI unresponsive

Siemens Sicharge D's touch HMI goes unresponsive or black while the station may continue reporting normally to OCPP, mea…

1 confirmed
WB-PP-WIFIWallbox · Pulsar Plus · AC Level 2 solo+

Wi-Fi drop loses schedule

Wallbox Pulsar Plus drops its Wi-Fi connection: scheduled charging and cloud-based authorization stop working while a lo…

3 confirmed
EVB-LV-COMEVBox · Livo · AC Level 2 solo+

Livo OCPP disconnect

EVBox Livo drops off the CSMS intermittently: Cloud shows Offline or repeated reconnects while the pedestal's local LEDs…

1 confirmed
CMS-AUTHAmpcontrol · Fleet CMSFree sample

Fleet CMS driver auth fail

A driver's credential or fleet app is rejected by the Ampcontrol CMS even though the charger hardware and OCPP path both look completely healthy — other drivers may authorize and charge normally at the exact same stall within minutes, which is the clearest signal that this is an enrollment or mapping problem in software rather than a reader or connector fault.

3 confirmed
CMS-OCPPAmpcontrol · Fleet CMS solo+

CMS-OCPP mapping wrong connector

The CMS's connector mapping doesn't match reality — a driver plugged into stall A is authorized, billed, and tracked as …

1 confirmed