The EVSE DirectorySubscribe

Fault database

Search by code, symptom, brand, category, or connector. Full procedures gated by subscription — look for green Free sample badges for open procedures.

Viewing as free

71 results · page 1 of 2

CCS-H01Cross-brand / Protocol · Cables & connectorsFree sample

CCS SLAC timeout

CCS SLAC timeout (CCS-H01) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H02Cross-brand / Protocol · Cables & connectorsFree sample

SDP failed — SECC not responding

SDP failed — SECC not responding (CCS-H02) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
CCS-H03Cross-brand / Protocol · Cables & connectorsFree sample

Cable check isolation fail

Cable check isolation fail (CCS-H03) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H04Cross-brand / Protocol · Cables & connectorsFree sample

Precharge voltage mismatch

Precharge voltage mismatch (CCS-H04) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
CCS-H05Cross-brand / Protocol · Cables & connectorsFree sample

Power delivery stops at CurrentDemand

Power delivery stops at CurrentDemand (CCS-H05) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
CCS-H06Cross-brand / Protocol · Cables & connectorsFree sample

Welding detection trip

Welding detection trip (CCS-H06) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H07Cross-brand / Protocol · Cables & connectorsFree sample

PP resistor out of range

PP resistor out of range (CCS-H07) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H08Cross-brand / Protocol · Cables & connectorsFree sample

CP state B stuck

CP state B stuck (CCS-H08) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
SEQ-01Cross-brand / Protocol · Cables & connectorsFree sample

EVSE ready before vehicle CP ready race

EVSE ready before vehicle CP ready race (SEQ-01) — Sequence / interlock field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
VEH-X01Cross-brand / Protocol · Cables & connectors solo+

Known vehicle profile needs CCS pause workaround

Known vehicle profile needs CCS pause workaround (VEH-X01) — Vehicle profile field fault. Stay OEM-agnostic until the pr…

1 confirmed
CCS-H09Cross-brand / Protocol · Cables & connectorsFree sample

SECC discovery wrong IP

SECC discovery wrong IP — vehicle cannot find SECC on the expected link-local/IP path; handshake dies at discovery/SDP. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on CCS-H09.

2 confirmed
CCS-H10Cross-brand / Protocol · Cables & connectorsFree sample

SessionSetup ResponseCode Failed

SessionSetup ResponseCode Failed (CCS-H10) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H11Cross-brand / Protocol · Cables & connectorsFree sample

EVSideCableCheck unknown error

EVSideCableCheck unknown error (CCS-H11) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
CP-E250-GFChargePoint · Express 250 · DC Fast ChargersFree sample

Ground fault trip under rain

Express 250 ground-fault trip under rain, wash-down, or wet holster — Cloud Faulted and local GF latch may refuse clear until the moisture path is proven dry. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-E250-GF.

2 confirmed
CP-E250-ISOChargePoint · Express 250 · DC Fast ChargersFree sample

Isolation fault after cable swap

Express 250 isolation fault before or during CableCheck after a cable swap, rain, or cooled-cable service — one gun or whole power cabinet. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-E250-ISO.

1 confirmed
CP-E250-FANChargePoint · Express 250 · DC Fast Chargers solo+

Power module fan fail

Express 250 power-module fan fail or thermal derate — loud/stopped fan, elevated module temps, or Cloud thermal events w…

2 confirmed
CP-E250-COMMChargePoint · Express 250 · DC Fast Chargers solo+

Dispenser-cabinet CAN loss

Express 250 dispenser–cabinet CAN/comm loss — dispenser UI dead or offline while the cabinet is still powered, or Cloud …

3 confirmed
CP-E250-DOORChargePoint · Express 250 · DC Fast Chargers solo+

Cabinet door interlock open

Express 250 cabinet door interlock open — station refuses energy or Faults while the door switch reports open even when …

2 confirmed
CP-E250-PFCChargePoint · Express 250 · DC Fast ChargersEarly access pro+

PFC stage overcurrent

ChargePoint PFC stage overcurrent (CP-E250-PFC) — confirm Express power cabinet vs dispenser ownership before parts. Fie…

1 confirmed
CP-E250-HDCChargePoint · Express 250 · DC Fast ChargersEarly access pro+

HDC contactor weld detect

ChargePoint HDC contactor weld detect (CP-E250-HDC) — confirm Express power cabinet vs dispenser ownership before parts.…

2 confirmed
CP-E250-RFIDChargePoint · Express 250 · DC Fast Chargers solo+

Station RFID unresponsive

Express 250 station RFID unresponsive — badge taps ignored while FreeVend or remote start may still work, pointing at th…

1 confirmed
CP-XP-COOLChargePoint · Express Plus · Liquid coolingEarly access pro+

Liquid cooling pump fail

ChargePoint Liquid cooling pump fail (CP-XP-COOL) — confirm Express power cabinet vs dispenser ownership before parts. F…

2 confirmed
CP-XP-NACSChargePoint · Express Plus · DC Fast ChargersFree sample

NACS port overtemp

Express Plus NACS port overtemp / derate — handle or inlet temps climb, session throttles or Faults, often in sun or after damaged handle work. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-XP-NACS.

3 confirmed
CP-XP-MODChargePoint · Express Plus · DC Fast ChargersEarly access pro+

Power brick offline

ChargePoint Power brick offline (CP-XP-MOD) — confirm Express power cabinet vs dispenser ownership before parts. Field t…

2 confirmed
CP-XP-LMSChargePoint · Express Plus · DC Fast Chargers solo+

Site LMS curtails Express Plus

Site LMS curtails Express Plus to near-zero amps — stalls look Faulted/Unavailable while power hardware is healthy and L…

3 confirmed
CP-XP-PAYChargePoint · Express Plus · Payment terminals solo+

Payment authorize timeout

Express Plus payment authorize timeout — PED spins or declines while FreeVend/RFID may work, splitting money path from e…

2 confirmed
ABB-T54-ISOABB · Terra 54 · DC Fast ChargersFree sample

Isolation error before charge

Terra 54 isolation error before charge — rain/cable/ISO path before power module blame. Field techs should correlate HMI/Cloud timestamps with Verify which gun and which stack faulted on dual-standard Terra sites.

2 confirmed
ABB-T54-CHAABB · Terra 54 · DC Fast Chargers solo+

CHAdeMO side no start

Terra 54 CHAdeMO side no start — CHAdeMO pilot/contactor path while CCS may still work. Field techs should correlate HMI…

3 confirmed
ABB-T54-CCSABB · Terra 54 · DC Fast ChargersFree sample

CCS connector latch fail

Terra 54 CCS connector latch fail — mechanical latch/actuator before SECC condemnation. Field techs should correlate HMI/Cloud timestamps with Verify which gun and which stack faulted on dual-standard Terra sites.

3 confirmed
ABB-T54-GRIDABB · Terra 54 · DC Fast Chargers solo+

Grid undervoltage trip

Terra 54 grid undervoltage trip — utility/feeder sag coinciding with charge start. Field techs should correlate HMI/Clou…

2 confirmed
ABB-T54-HMIABB · Terra 54 · DC Fast Chargers solo+

HMI frozen on Fault

Terra 54 HMI frozen on Fault — UI locked; confirm whether power path still live underneath. Field techs should correlate…

2 confirmed
ABB-T54-SENSABB · Terra 54 · DC Fast Chargers solo+

Temp sensor open circuit

Terra 54 temp sensor open circuit — thermal derate/fault from open sensor harness. Field techs should correlate HMI/Clou…

2 confirmed
ABB-T54-FWABB · Terra 54 · DC Fast ChargersEarly access pro+

Boot loop after FW flash

Terra 54 boot loop after FW flash — early-access recovery per ABB, not module shotgun. Field techs should correlate HMI/…

2 confirmed
ABB-T184-PMABB · Terra 184 · DC Fast ChargersEarly access pro+

Power module imbalance

Terra 184 power module imbalance — early-access: one module not sharing current. Field techs should correlate HMI/Cloud …

2 confirmed
ABB-T184-COOLABB · Terra 184 · Liquid coolingFree sample

Coolant flow low

Terra 184 coolant flow low — bleed/leak/sensor before condemning the whole cooling skid. Field techs should correlate HMI/Cloud timestamps with Verify which gun and which stack faulted on dual-standard Terra sites.

2 confirmed
ABB-T184-COMABB · Terra 184 · DC Fast Chargers solo+

OCPP disconnect after peak

Terra 184 OCPP disconnect after peak — Soft-offline under load/heat, prove backhaul vs controller. Field techs should co…

2 confirmed
ABB-T184-ESTOPABB · Terra 184 · DC Fast ChargersEarly access pro+

E-stop loop intermittent

Terra 184 E-stop loop intermittent — early-access: loop/wiring before blaming stacks. Field techs should correlate HMI/C…

1 confirmed
ABB-T184-METABB · Terra 184 · DC Fast Chargers solo+

Energy register jump

Terra 184 energy register jump — metering discontinuity; billing/integrity before power RMA. Field techs should correlat…

2 confirmed
TRI-PK-ISOTritium · PK350 · DC Fast ChargersFree sample

PK350 isolation fault

PK350 isolation fault — cooled-cable/moisture path; PK liquid-cooled rules differ from RTM air-cooled. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.

1 confirmed
TRI-PK-CABLETritium · PK350 · Liquid coolingFree sample

Liquid-cooled cable leak detect

PK350 liquid-cooled cable leak detect — contain spill, reseal/replace path, bleed before return to service. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.

3 confirmed