CP-XP-LMSChargePoint · Express Plus · DC Fast Chargers solo+

Site LMS curtails Express Plus

Site LMS curtails Express Plus on chargepoint (express-plus): ChargePoint station HMI / Cloud diagnostics shows CP-XP-LM…

3 confirmed
CCS-H03Cross-brand / Protocol · Cables & connectorsFree sample

Cable check isolation fail

Cable check isolation fail on protocol: CSMS StatusNotification + connector LEDs shows CCS-H03. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate OCPP websocket / SECC / vehicle logs as applicable before opening the cabinet.

2 confirmed
ABB-T54-GRIDABB · Terra 54 · DC Fast Chargers solo+

Grid undervoltage trip

Grid undervoltage trip on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-GRID. Techs see sessio…

2 confirmed
CAB-PINSite stack (generic) · Cables & connectors solo+

CCS pin burnt

CCS pin burnt on site-generic: Site LMS / breaker / skid local indicators shows CAB-PIN. Techs see session abort or stal…

1 confirmed
CCS-H02Cross-brand / Protocol · Cables & connectors solo+

SDP failed — SECC not responding

SDP failed — SECC not responding on protocol: CSMS StatusNotification + connector LEDs shows CCS-H02. Techs see session …

3 confirmed
BTC-HP-ISOBTC Power · HP150 · DC Fast ChargersFree sample

HP150 isolation trip

HP150 isolation trip on btc-power (hp150): BTC Power local display / LED bank shows BTC-HP-ISO. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate BTC CSMS + cabinet PLC event list before opening the cabinet.

1 confirmed
DEL-UFC-LOCKDelta · UFC100 · DC Fast Chargers solo+

Connector lock motor fail

Connector lock motor fail on delta (ufc100): Delta UFC HMI shows DEL-UFC-LOCK. Techs see session abort or stall Unavaila…

1 confirmed
BTC-HP-PFCBTC Power · HP150 · DC Fast Chargers solo+

Input PFC fault

Input PFC fault on btc-power (hp150): BTC Power local display / LED bank shows BTC-HP-PFC. Techs see session abort or st…

2 confirmed
DEL-UFC-COMDelta · UFC100 · DC Fast Chargers solo+

Backend unreachable

Backend unreachable on delta (ufc100): Delta UFC HMI shows DEL-UFC-COM. Techs see session abort or stall Unavailable unt…

2 confirmed
ABB-T54-SENSABB · Terra 54 · DC Fast Chargers solo+

Temp sensor open circuit

Temp sensor open circuit on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-SENS. Techs see sess…

2 confirmed
TRI-RTM-GFTritium · RTM75 · DC Fast ChargersFree sample

RTM ground fault

RTM ground fault on tritium (rtm75): Tritium dispenser UI / RTM or PK service LED shows TRI-RTM-GF. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate Tritium Veefil / OCPP vendor DataTransfer if enabled before opening the cabinet.

3 confirmed
ABB-T54-CCSABB · Terra 54 · DC Fast ChargersFree sample

CCS connector latch fail

CCS connector latch fail on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-CCS. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ABB Connected Services / OCPP StatusNotification info before opening the cabinet.

3 confirmed
AUT-MC-APPAutel · MaxiCharger DC · DC Fast Chargers solo+

App start fails OCPP ok

App start fails OCPP ok on autel (maxicharger-dc): MaxiCharger DC screen shows AUT-MC-APP. Techs see session abort or st…

2 confirmed
BTC-HP-DOORBTC Power · HP150 · DC Fast Chargers solo+

Service door switch bounce

Service door switch bounce on btc-power (hp150): BTC Power local display / LED bank shows BTC-HP-DOOR. Techs see session…

3 confirmed
CP-XP-PAYChargePoint · Express Plus · Payment terminals solo+

Payment authorize timeout

Payment authorize timeout on chargepoint (express-plus): ChargePoint station HMI / Cloud diagnostics shows CP-XP-PAY. Te…

2 confirmed
CCS-H01Cross-brand / Protocol · Cables & connectorsFree sample

CCS SLAC timeout

CCS SLAC timeout on protocol: CSMS StatusNotification + connector LEDs shows CCS-H01. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate OCPP websocket / SECC / vehicle logs as applicable before opening the cabinet.

2 confirmed
PE-NB-GRIDPower Electronics · NB 360 · DC Fast Chargers solo+

Input phase loss

Input phase loss on power-electronics (nb-360): NB series HMI / keypad shows PE-NB-GRID. Techs see session abort or stal…

2 confirmed
DEL-UFC-FANDelta · UFC100 · DC Fast Chargers solo+

Exhaust fan fault

Exhaust fan fault on delta (ufc100): Delta UFC HMI shows DEL-UFC-FAN. Techs see session abort or stall Unavailable until…

3 confirmed
CP-E250-FANChargePoint · Express 250 · DC Fast Chargers solo+

Power module fan fail

Power module fan fail on chargepoint (express-250): ChargePoint station HMI / Cloud diagnostics shows CP-E250-FAN. Techs…

2 confirmed
VEH-X01Cross-brand / Protocol · Cables & connectors solo+

Known vehicle profile needs CCS pause workaround

Known vehicle profile needs CCS pause workaround: charger or site equipment presents this pattern under load or on sessi…

1 confirmed
BTC-HP-OCPPBTC Power · HP150 · DC Fast Chargers solo+

OCPP reconnect storm

OCPP reconnect storm on btc-power (hp150): BTC Power local display / LED bank shows BTC-HP-OCPP. Techs see session abort…

1 confirmed
SEQ-01Cross-brand / Protocol · Cables & connectors solo+

EVSE ready before vehicle CP ready race

EVSE ready before vehicle CP ready race: charger or site equipment presents this pattern under load or on session start.…

2 confirmed
KEM-SAT-RFIDKempower · Satellite · DC Fast Chargers solo+

RFID reader miswired after service

RFID reader miswired after service on kempower (satellite): Kempower Satellite / C-series UI shows KEM-SAT-RFID. Techs s…

3 confirmed
CP-E250-ISOChargePoint · Express 250 · DC Fast ChargersFree sample

Isolation fault after cable swap

Isolation fault after cable swap on chargepoint (express-250): ChargePoint station HMI / Cloud diagnostics shows CP-E250-ISO. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ChargePoint Cloud session + station event log before opening the cabinet.

1 confirmed
BTC-HP-NACSBTC Power · HP150 · DC Fast Chargers solo+

NACS adapter path fault

NACS adapter path fault on btc-power (hp150): BTC Power local display / LED bank shows BTC-HP-NACS. Techs see session ab…

1 confirmed
CP-XP-NACSChargePoint · Express Plus · DC Fast ChargersFree sample

NACS port overtemp

NACS port overtemp on chargepoint (express-plus): ChargePoint station HMI / Cloud diagnostics shows CP-XP-NACS. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ChargePoint Cloud session + station event log before opening the cabinet.

3 confirmed
TRI-RTM-AUTHTritium · RTM75 · DC Fast Chargers solo+

Auth timeout local list empty

Auth timeout local list empty on tritium (rtm75): Tritium dispenser UI / RTM or PK service LED shows TRI-RTM-AUTH. Techs…

2 confirmed
PE-NB-ISOPower Electronics · NB 360 · DC Fast Chargers solo+

NB360 isolation

NB360 isolation on power-electronics (nb-360): NB series HMI / keypad shows PE-NB-ISO. Techs see session abort or stall …

2 confirmed
ABB-T184-METABB · Terra 184 · DC Fast Chargers solo+

Energy register jump

Energy register jump on abb (terra-184): ABB Terra HMI fault banner + service menu shows ABB-T184-MET. Techs see session…

2 confirmed
CP-E250-GFChargePoint · Express 250 · DC Fast ChargersFree sample

Ground fault trip under rain

Ground fault trip under rain on chargepoint (express-250): ChargePoint station HMI / Cloud diagnostics shows CP-E250-GF. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ChargePoint Cloud session + station event log before opening the cabinet.

2 confirmed
DEL-UFC-GFDelta · UFC100 · DC Fast Chargers solo+

UFC ground fault

UFC ground fault on delta (ufc100): Delta UFC HMI shows DEL-UFC-GF. Techs see session abort or stall Unavailable until t…