CCS-H01Cross-brand / Protocol · Cables & connectorsFree sample

CCS SLAC timeout

CCS SLAC timeout (CCS-H01) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H02Cross-brand / Protocol · Cables & connectorsFree sample

SDP failed — SECC not responding

SDP failed — SECC not responding (CCS-H02) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
CCS-H03Cross-brand / Protocol · Cables & connectorsFree sample

Cable check isolation fail

Cable check isolation fail (CCS-H03) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H04Cross-brand / Protocol · Cables & connectorsFree sample

Precharge voltage mismatch

Precharge voltage mismatch (CCS-H04) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
CCS-H05Cross-brand / Protocol · Cables & connectorsFree sample

Power delivery stops at CurrentDemand

Power delivery stops at CurrentDemand (CCS-H05) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
CCS-H06Cross-brand / Protocol · Cables & connectorsFree sample

Welding detection trip

Welding detection trip (CCS-H06) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H07Cross-brand / Protocol · Cables & connectorsFree sample

PP resistor out of range

PP resistor out of range (CCS-H07) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H08Cross-brand / Protocol · Cables & connectorsFree sample

CP state B stuck

CP state B stuck (CCS-H08) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
SEQ-01Cross-brand / Protocol · Cables & connectorsFree sample

EVSE ready before vehicle CP ready race

EVSE ready before vehicle CP ready race (SEQ-01) — Sequence / interlock field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
VEH-X01Cross-brand / Protocol · Cables & connectors solo+

Known vehicle profile needs CCS pause workaround

Known vehicle profile needs CCS pause workaround (VEH-X01) — Vehicle profile field fault. Stay OEM-agnostic until the pr…

1 confirmed
CCS-H09Cross-brand / Protocol · Cables & connectorsFree sample

SECC discovery wrong IP

SECC discovery wrong IP — vehicle cannot find SECC on the expected link-local/IP path; handshake dies at discovery/SDP. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on CCS-H09.

2 confirmed
CCS-H10Cross-brand / Protocol · Cables & connectorsFree sample

SessionSetup ResponseCode Failed

SessionSetup ResponseCode Failed (CCS-H10) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CCS-H11Cross-brand / Protocol · Cables & connectorsFree sample

EVSideCableCheck unknown error

EVSideCableCheck unknown error (CCS-H11) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
ABB-T54-CCSABB · Terra 54 · DC Fast ChargersFree sample

CCS connector latch fail

Terra 54 CCS connector latch fail — mechanical latch/actuator before SECC condemnation. Field techs should correlate HMI/Cloud timestamps with Verify which gun and which stack faulted on dual-standard Terra sites.

3 confirmed
ABB-T184-PMABB · Terra 184 · DC Fast ChargersEarly access pro+

Power module imbalance

Terra 184 power module imbalance — early-access: one module not sharing current. Field techs should correlate HMI/Cloud …

2 confirmed
ABB-T184-COOLABB · Terra 184 · Liquid coolingFree sample

Coolant flow low

Terra 184 coolant flow low — bleed/leak/sensor before condemning the whole cooling skid. Field techs should correlate HMI/Cloud timestamps with Verify which gun and which stack faulted on dual-standard Terra sites.

2 confirmed
ABB-T184-COMABB · Terra 184 · DC Fast Chargers solo+

OCPP disconnect after peak

Terra 184 OCPP disconnect after peak — Soft-offline under load/heat, prove backhaul vs controller. Field techs should co…

2 confirmed
ABB-T184-ESTOPABB · Terra 184 · DC Fast ChargersEarly access pro+

E-stop loop intermittent

Terra 184 E-stop loop intermittent — early-access: loop/wiring before blaming stacks. Field techs should correlate HMI/C…

1 confirmed
ABB-T184-METABB · Terra 184 · DC Fast Chargers solo+

Energy register jump

Terra 184 energy register jump — metering discontinuity; billing/integrity before power RMA. Field techs should correlat…

2 confirmed
TRI-PK-ISOTritium · PK350 · DC Fast ChargersFree sample

PK350 isolation fault

PK350 isolation fault — cooled-cable/moisture path; PK liquid-cooled rules differ from RTM air-cooled. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.

1 confirmed
TRI-PK-CABLETritium · PK350 · Liquid coolingFree sample

Liquid-cooled cable leak detect

PK350 liquid-cooled cable leak detect — contain spill, reseal/replace path, bleed before return to service. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.

3 confirmed
TRI-PK-DISPTritium · PK350 · DC Fast Chargers solo+

Dispenser UI no boot

PK dispenser UI no boot — HMI/SBC path while power cabinet may still be alive. Field techs should correlate HMI/Cloud ti…

2 confirmed
TRI-PK-PWRTritium · PK350 · DC Fast ChargersEarly access pro+

Rectifier stage fault

PK rectifier stage fault — early-access HV power stage; LOTO and OEM diagnostics. Field techs should correlate HMI/Cloud…

3 confirmed
TRI-PK-NETTritium · PK350 · DC Fast ChargersEarly access pro+

Cellular failover flapping

PK cellular failover flapping — early-access modem/SIM/DNS path before board RMA. Field techs should correlate HMI/Cloud…

1 confirmed
TRI-PK-GUNTritium · PK350 · DC Fast Chargers solo+

Gun temperature derate

PK gun temperature derate — handle/contact heat or sensor; sun and damaged guns rank high. Field techs should correlate …

3 confirmed
KEM-SAT-LINKKempower · Satellite · DC Fast ChargersFree sample

Satellite link to power unit lost

Kempower Satellite link to power unit lost — satellite/dynamic pool link before condemning the dispenser. Field techs should correlate HMI/Cloud timestamps with Satellite dynamic power pool — confirm module pool assignment before condemning a stall

3 confirmed
KEM-SAT-DYNKempower · Satellite · DC Fast ChargersEarly access pro+

Dynamic power allocation stuck

Kempower dynamic power pool fault — early-access pool assignment/module map issues. Field techs should correlate HMI/Clo…

2 confirmed
KEM-SAT-CCSKempower · Satellite · DC Fast Chargers solo+

CCS session abort mid-ramp

Kempower CCS session abort mid-ramp — handshake/current share under dynamic pool assignment. Field techs should correlat…

1 confirmed
KEM-SAT-COOLKempower · Satellite · Liquid cooling solo+

Cabinet coolant pressure low

Kempower cabinet coolant pressure low — cooling loop/pressure before module RMA. Field techs should correlate HMI/Cloud …

2 confirmed
KEM-SAT-RFIDKempower · Satellite · DC Fast Chargers solo+

RFID reader miswired after service

Kempower RFID reader miswired after service — auth path vs energy path. Field techs should correlate HMI/Cloud timestamp…

3 confirmed
CAB-PINSite stack (generic) · Cables & connectors solo+

CCS pin burnt

CCS pin burnt — overheating/arcing damage on power pins from high resistance or partial latch. site-generic field note: …

1 confirmed
ALP-HYC-ISOAlpitronic · HYC300 · DC Fast ChargersFree sample

HYC isolation fault

Alpitronic Hypercharger fails isolation during CableCheck on one connector, or occasionally across the whole cabinet, most often after rain, a cable swap, or overnight condensation. Because HYC300 modules share a common coolant loop, a wet or contaminated path on one gun can occasionally present as a broader isolation issue across the bank.

2 confirmed
ALP-HYC-MODAlpitronic · HYC300 · DC Fast ChargersEarly access pro+

Module offline bank

One Alpitronic Hypercharger power module drops offline within its bank, showing up as reduced maximum kW, an imbalanced …

2 confirmed
ALP-HYC-PAYAlpitronic · HYC300 · Payment terminals solo+

Payment terminal offline

Alpitronic Hypercharger's onboard payment terminal goes offline while the energy delivery path may continue operating un…

2 confirmed
ALP-HYC-GRIDAlpitronic · HYC300 · DC Fast Chargers solo+

Grid overvoltage

Alpitronic Hypercharger trips on grid overvoltage, aborting active sessions and refusing new ones until the input voltag…

2 confirmed
SIE-SD-ISOSiemens · Sicharge D · DC Fast ChargersFree sample

Sicharge isolation

Siemens Sicharge D reports an isolation fault on one connector path while the peer gun on the same cabinet may remain Available, and technicians must confirm whether the power cabinet or the dispenser head owns the failing measurement before opening either enclosure. Weather exposure and recent cable service are the most common triggers.

1 confirmed
SIE-SD-LMSSiemens · Sicharge D · DC Fast ChargersEarly access pro+

Cluster LMS conflict

Siemens Sicharge D cluster experiences a load-management conflict where multiple stalls fight over the site's power budg…

3 confirmed
SIE-SD-METSiemens · Sicharge D · DC Fast Chargers solo+

MID meter fault

Siemens Sicharge D's MID fiscal meter reports a fault that either blocks billed sessions entirely or produces incorrect …

1 confirmed
SIE-SD-HMISiemens · Sicharge D · DC Fast Chargers solo+

Touch HMI unresponsive

Siemens Sicharge D's touch HMI goes unresponsive or black while the station may continue reporting normally to OCPP, mea…