The EVSE DirectorySubscribe

Fault database

Search by code, symptom, brand, category, or connector. Full procedures gated by subscription — look for green Free sample badges for open procedures.

Viewing as free

20 results

NACS-H01Cross-brand / Protocol · Cables & connectorsFree sample

NACS handshake timeout on adapter path

NACS handshake timeout on adapter path (NACS-H01) — NACS path field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
NACS-H02Cross-brand / Protocol · Cables & connectorsFree sample

NACS proximity detect intermittent

NACS proximity detect intermittent (NACS-H02) — NACS path field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
NACS-H03Cross-brand / Protocol · Cables & connectorsFree sample

NACS thermal derate to zero

NACS thermal derate to zero (NACS-H03) — NACS path field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
VEH-X03Cross-brand / Protocol · Cables & connectors solo+

NACS native vehicle on CCS1-only dispenser

NACS native vehicle on CCS1-only dispenser (VEH-X03) — Vehicle profile field fault. Stay OEM-agnostic until the protocol…

3 confirmed
NACS-H04Cross-brand / Protocol · Cables & connectorsFree sample

NACS PP open mid-session

NACS PP open mid-session (NACS-H04) — NACS path field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
CP-XP-COOLChargePoint · Express Plus · Liquid coolingEarly access pro+

Liquid cooling pump fail

ChargePoint Liquid cooling pump fail (CP-XP-COOL) — confirm Express power cabinet vs dispenser ownership before parts. F…

2 confirmed
CP-XP-NACSChargePoint · Express Plus · DC Fast ChargersFree sample

NACS port overtemp

Express Plus NACS port overtemp / derate — handle or inlet temps climb, session throttles or Faults, often in sun or after damaged handle work. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-XP-NACS.

3 confirmed
CP-XP-MODChargePoint · Express Plus · DC Fast ChargersEarly access pro+

Power brick offline

ChargePoint Power brick offline (CP-XP-MOD) — confirm Express power cabinet vs dispenser ownership before parts. Field t…

2 confirmed
CP-XP-LMSChargePoint · Express Plus · DC Fast Chargers solo+

Site LMS curtails Express Plus

Site LMS curtails Express Plus to near-zero amps — stalls look Faulted/Unavailable while power hardware is healthy and L…

3 confirmed
CP-XP-PAYChargePoint · Express Plus · Payment terminals solo+

Payment authorize timeout

Express Plus payment authorize timeout — PED spins or declines while FreeVend/RFID may work, splitting money path from e…

2 confirmed
BTC-HP-ISOBTC Power · HP150 · DC Fast ChargersFree sample

HP150 isolation trip

BTC HP150 isolation trip — cable/moisture/ISO path on HP family before power-module crates. Field techs should correlate HMI/Cloud timestamps with HP family often needs power-cabinet vs dispenser CAN check before module swap

1 confirmed
BTC-HP-NACSBTC Power · HP150 · DC Fast Chargers solo+

NACS adapter path fault

BTC HP NACS adapter path fault — adapter/port thermal or proximity before CCS stack blame. Field techs should correlate …

1 confirmed
BTC-HP-DOORBTC Power · HP150 · DC Fast Chargers solo+

Service door switch bounce

BTC HP service door switch bounce — interlock chatter after service; never jumper. Field techs should correlate HMI/Clou…

3 confirmed
BTC-HP-PFCBTC Power · HP150 · DC Fast Chargers solo+

Input PFC fault

BTC HP input PFC fault — grid/PFC stage under load; correlate site voltage. Field techs should correlate HMI/Cloud times…

2 confirmed
BTC-HP-OCPPBTC Power · HP150 · DC Fast Chargers solo+

OCPP reconnect storm

BTC HP OCPP reconnect storm — Soft-offline reconnect loops; backhaul/config before boards. Field techs should correlate …

1 confirmed
CAB-NACSSite stack (generic) · Cables & connectors solo+

NACS handle overtemp

NACS handle overtemp — NACS path thermal derate/fault from handle or inlet heat. site-generic field note: keep evidence …

2 confirmed
AUT-MC-ISOAutel · MaxiCharger DC · DC Fast ChargersFree sample

MaxiCharger isolation

Autel MaxiCharger DC fails isolation/CableCheck on one connector while the peer port on the same dual-standard unit stays healthy. Because MaxiCharger DC often pairs a CCS and NACS port from a shared cabinet, techs must confirm which physical port and which cable actually failed before assuming a cabinet-wide isolation fault.

3 confirmed
AUT-MC-NACSAutel · MaxiCharger DC · DC Fast ChargersFree sample

NACS port latch

Autel MaxiCharger DC's NACS port latch fails to lock or won't release, either preventing a session from starting because the vehicle never confirms a locked connector, or trapping the cable in the vehicle inlet after the session ends. Drivers often report a buzzing sound or visible resistance when inserting the NACS handle.

2 confirmed
AUT-MC-APPAutel · MaxiCharger DC · DC Fast Chargers solo+

App start fails OCPP ok

Autel MaxiCharger DC app-initiated sessions fail to start while OCPP Heartbeat continues normally to the CSMS, meaning t…

2 confirmed
AUT-MC-THERMAutel · MaxiCharger DC · DC Fast ChargersFree sample

Power stage overtemp

Autel MaxiCharger DC power stage overtemp shows up as a progressive derate during sustained high-power sessions, escalating to a full Faulted stop if airflow or ambient conditions don't improve. This is most common in summer at sites with blocked intake filters, undersized clearance around the cabinet, or back-to-back long sessions with little cooldown between them.

1 confirmed