Search by code, symptom, brand, category, or connector. Full procedures gated by subscription — look for green Free sample badges for open procedures.

Viewing as free

212 results · page 4 of 6

CTR-WELDSite stack (generic) · Contactors & protectionFree sample

Main DC contactor welded

Main DC contactor welded — weld detect or stuck-closed feedback after high-cycle use; do not force energy. site-generic field note: keep evidence scrubbed and prove the ranked cause before module RMA on CTR-WELD.

1 confirmed
CTR-COILSite stack (generic) · Contactors & protection solo+

Contactor coil open

Contactor coil open — contactor will not pull in; coil circuit open or driver failed. site-generic field note: keep evid…

2 confirmed
BRK-TRIPSite stack (generic) · Contactors & protection solo+

Feeder breaker nuisance trip

Feeder breaker nuisance trip — pad or cabinet feeder opens under EVSE ramp; often PQ/settings not a single module. site-…

3 confirmed
SPD-FAILSite stack (generic) · Contactors & protection solo+

SPD end-of-life indicated

SPD end-of-life indicated — surge protector flag/window shows spent; replace before the next surge event. site-generic f…

2 confirmed
RCD-TESTSite stack (generic) · Contactors & protection solo+

RCD fails monthly test

RCD fails monthly test — protective device does not trip on test or will not reset; treat as protection failure. site-ge…

2 confirmed
COOL-PUMPSite stack (generic) · Coolant skid · Liquid cooling solo+

Coolant pump no flow

Coolant pump no flow — pump alarm/thermal derate with zero inferred flow on liquid-cooled skid. site-generic field note:…

3 confirmed
COOL-LEAKSite stack (generic) · Coolant skid · Liquid cooling solo+

Glycol leak at quick-connect

Glycol leak at quick-connect — visible drip or pressure loss at gun/skid QD after cable work. site-generic field note: k…

3 confirmed
COOL-AIRSite stack (generic) · Coolant skid · Liquid cooling solo+

Airlocked loop after fill

Airlocked loop after fill — pump runs but cooling ineffective until bleed removes air. site-generic field note: keep evi…

1 confirmed
COOL-SENSSite stack (generic) · Coolant skid · Liquid cooling solo+

Flow sensor false low

Flow sensor false low — cooling actually fine by IR/pressure but sensor reports low flow. site-generic field note: keep …

1 confirmed
CAB-IRSite stack (generic) · Cables & connectors solo+

Cable IR insulation fail

Cable IR insulation fail — insulation resistance below OEM limit on DC cable path. site-generic field note: keep evidenc…

2 confirmed
CAB-PINSite stack (generic) · Cables & connectors solo+

CCS pin burnt

CCS pin burnt — overheating/arcing damage on power pins from high resistance or partial latch. site-generic field note: …

1 confirmed
CAB-LATCHSite stack (generic) · Cables & connectors solo+

Latch microswitch false open

Latch microswitch false open — charger thinks latch open while mechanically latched. site-generic field note: keep evide…

3 confirmed
CAB-STRAINSite stack (generic) · Cables & connectors solo+

Strain relief broken

Strain relief broken — cable jacket control failed; conductors flex/fatigue at gland. site-generic field note: keep evid…

1 confirmed
LMS-ZEROSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

LMS allocates 0 A all ports

LMS allocates 0 A all ports — site controller sets zero budget; stalls idle with healthy hardware. site-generic field no…

1 confirmed
LMS-COMSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

LMS PLC offline

LMS PLC offline — chargers lose LMS and enter failsafe curtail/Unavailable. site-generic field note: keep evidence scrub…

3 confirmed
CAB-FANSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

Power cabinet fan fail

Power cabinet fan fail — thermal alarms with stopped or noisy cabinet fans on the site power cabinet, often after dusty …

1 confirmed
CAB-BUSSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

DC bus undervoltage

DC bus undervoltage — bus collapses under load from grid/feed or module issues. site-generic field note: keep evidence s…

2 confirmed
CAB-PARSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

Parallel cabinet sync fail

Parallel cabinet sync fail — paralleled cabinets refuse to share or sync DC bus. site-generic field note: keep evidence …

3 confirmed
PAY-NFCIngenico / payment · Self/4000 family · Payment terminals solo+

NFC tap intermittent

NFC tap intermittent — antenna/cable/EMI; prove with multiple cards. Field techs should correlate HMI/Cloud timestamps w…

2 confirmed
MDM-APNSierra Wireless / Semtech · AirLink modem · Modem / cellular solo+

Wrong APN after SIM swap

Wrong APN after SIM swap — classic Soft-offline after carrier change. Field techs should correlate HMI/Cloud timestamps …

2 confirmed
CAB-NACSSite stack (generic) · Cables & connectors solo+

NACS handle overtemp

NACS handle overtemp — NACS path thermal derate/fault from handle or inlet heat. site-generic field note: keep evidence …

2 confirmed
CTR-AUXSite stack (generic) · Contactors & protection solo+

Aux contact feedback mismatch

Aux contact feedback mismatch — controller sees disagreement between command and aux, blocking sessions. site-generic fi…

2 confirmed
DEP-CURTSite stack (generic) · Power cabinet / LMS solo+

Depot LMS curtails on demand response

Depot LMS curtails on demand response — scheduled DR event cuts amps across the depot. site-generic field note: keep evi…

1 confirmed
DEP-SEQSite stack (generic) · Power cabinet / LMS solo+

Sequential start brownout

Sequential start brownout — too many stalls authorize together; voltage sag trips protection. site-generic field note: k…

2 confirmed
DEP-ISLANDSite stack (generic) · BESS solo+

Island mode leaves EVSE dark

Island mode leaves EVSE dark — site generation/BESS island excludes EVSE bus or opens intertie. site-generic field note:…

1 confirmed
DEP-XFMR-TAPSite stack (generic) · Switchgear solo+

Wrong tap leaves undervoltage

Wrong tap leaves undervoltage — transformer tap leaves EVSE bus low under load. site-generic field note: keep evidence s…

1 confirmed
ALP-HYC-ISOAlpitronic · HYC300 · DC Fast ChargersFree sample

HYC isolation fault

Alpitronic Hypercharger fails isolation during CableCheck on one connector, or occasionally across the whole cabinet, most often after rain, a cable swap, or overnight condensation. Because HYC300 modules share a common coolant loop, a wet or contaminated path on one gun can occasionally present as a broader isolation issue across the bank.

2 confirmed
ALP-HYC-MODAlpitronic · HYC300 · DC Fast ChargersEarly access pro+

Module offline bank

One Alpitronic Hypercharger power module drops offline within its bank, showing up as reduced maximum kW, an imbalanced …

2 confirmed
ALP-HYC-PAYAlpitronic · HYC300 · Payment terminals solo+

Payment terminal offline

Alpitronic Hypercharger's onboard payment terminal goes offline while the energy delivery path may continue operating un…

2 confirmed
ALP-HYC-GRIDAlpitronic · HYC300 · DC Fast Chargers solo+

Grid overvoltage

Alpitronic Hypercharger trips on grid overvoltage, aborting active sessions and refusing new ones until the input voltag…

2 confirmed
DEL-UFC-GFDelta · UFC100 · DC Fast ChargersFree sample

UFC ground fault

Delta UFC100 dispenser trips ground fault mid-session or during CableCheck, most often after rain, wash-down, or a recent cable service call. HMI banner reads Ground Fault while OCPP reports Faulted/GroundFailure; the fault can lock a single gun or take the whole cabinet Unavailable if the sensing sits upstream of the split.

2 confirmed
DEL-UFC-COMDelta · UFC100 · DC Fast ChargersFree sample

Backend unreachable

Delta UFC100 loses its link to CSMS/cloud while the local HMI may still show Ready or Available, creating a mismatch where drivers see a working screen but the backend lists the station offline or flapping. Heartbeat gaps and delayed StatusNotification are the giveaway; sessions started locally may not sync until the link recovers.

2 confirmed
DEL-UFC-FANDelta · UFC100 · DC Fast Chargers solo+

Exhaust fan fault

Delta UFC100 exhaust fan fault raises internal cabinet temperature during high-power sessions, first showing as a derate…

3 confirmed
DEL-UFC-LOCKDelta · UFC100 · DC Fast Chargers solo+

Connector lock motor fail

Delta UFC100 connector lock motor fails to latch or release the CCS handle, leaving a session unable to start or a cable…

1 confirmed
AUT-MC-ISOAutel · MaxiCharger DC · DC Fast ChargersFree sample

MaxiCharger isolation

Autel MaxiCharger DC fails isolation/CableCheck on one connector while the peer port on the same dual-standard unit stays healthy. Because MaxiCharger DC often pairs a CCS and NACS port from a shared cabinet, techs must confirm which physical port and which cable actually failed before assuming a cabinet-wide isolation fault.

3 confirmed
AUT-MC-NACSAutel · MaxiCharger DC · DC Fast ChargersFree sample

NACS port latch

Autel MaxiCharger DC's NACS port latch fails to lock or won't release, either preventing a session from starting because the vehicle never confirms a locked connector, or trapping the cable in the vehicle inlet after the session ends. Drivers often report a buzzing sound or visible resistance when inserting the NACS handle.

2 confirmed
AUT-MC-APPAutel · MaxiCharger DC · DC Fast Chargers solo+

App start fails OCPP ok

Autel MaxiCharger DC app-initiated sessions fail to start while OCPP Heartbeat continues normally to the CSMS, meaning t…

2 confirmed
AUT-MC-THERMAutel · MaxiCharger DC · DC Fast ChargersFree sample

Power stage overtemp

Autel MaxiCharger DC power stage overtemp shows up as a progressive derate during sustained high-power sessions, escalating to a full Faulted stop if airflow or ambient conditions don't improve. This is most common in summer at sites with blocked intake filters, undersized clearance around the cabinet, or back-to-back long sessions with little cooldown between them.

1 confirmed
SIE-SD-ISOSiemens · Sicharge D · DC Fast ChargersFree sample

Sicharge isolation

Siemens Sicharge D reports an isolation fault on one connector path while the peer gun on the same cabinet may remain Available, and technicians must confirm whether the power cabinet or the dispenser head owns the failing measurement before opening either enclosure. Weather exposure and recent cable service are the most common triggers.

1 confirmed
SIE-SD-LMSSiemens · Sicharge D · DC Fast ChargersEarly access pro+

Cluster LMS conflict

Siemens Sicharge D cluster experiences a load-management conflict where multiple stalls fight over the site's power budg…

3 confirmed