Arcbound FieldThe EVSE DirectorySubscribe

Fault database

Search by code, symptom, brand, category, or connector. Full procedures gated by subscription — samples stay open.

Viewing as free

212 results · page 2 of 6

ABB-T54-CHAABB · Terra 54 · DC Fast Chargers solo+

CHAdeMO side no start

CHAdeMO side no start on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-CHA. Techs see session …

3 confirmed
KEM-SAT-COOLKempower · Satellite · Liquid cooling solo+

Cabinet coolant pressure low

Cabinet coolant pressure low on kempower (satellite): Kempower Satellite / C-series UI shows KEM-SAT-COOL. Techs see ses…

2 confirmed
EVB-LV-COMEVBox · Livo · AC Level 2 solo+

Livo OCPP disconnect

Livo OCPP disconnect: charger or site equipment presents this pattern under load or on session start. Techs report inter…

1 confirmed
CAB-FANSite stack (generic) · LMS / power cabinet · Power cabinet / LMS solo+

Power cabinet fan fail

Power cabinet fan fail on site-generic: Site LMS / breaker / skid local indicators shows CAB-FAN. Techs see session abor…

1 confirmed
DEP-CURTSite stack (generic) · Power cabinet / LMS solo+

Depot LMS curtails on demand response

Depot LMS curtails on demand response on site-generic: Site LMS / breaker / skid local indicators shows DEP-CURT. Techs …

1 confirmed
OCPP-F01Cross-brand / Protocol · DC Fast ChargersFree sample

StatusNotification stuck Faulted after reboot

StatusNotification stuck Faulted after reboot on protocol: CSMS StatusNotification + connector LEDs shows OCPP-F01. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate OCPP websocket / SECC / vehicle logs as applicable before opening the cabinet.

3 confirmed
ABB-T54-HMIABB · Terra 54 · DC Fast Chargers solo+

HMI frozen on Fault

HMI frozen on Fault on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-HMI. Techs see session ab…

2 confirmed
PAY-CHIPIngenico / payment · Self/4000 family · Payment terminals solo+

Chip read fail wet weather

Chip read fail wet weather on ingenico: PED screen / host response code shows PAY-CHIP. Techs see session abort or stall…

1 confirmed
COOL-LEAKSite stack (generic) · Coolant skid · Liquid cooling solo+

Glycol leak at quick-connect

Glycol leak at quick-connect on site-generic: Site LMS / breaker / skid local indicators shows COOL-LEAK. Techs see sess…

3 confirmed
ISO-H03Cross-brand / Protocol · Cables & connectors solo+

Schedule renegotiation abort

Schedule renegotiation abort: charger or site equipment presents this pattern under load or on session start. Techs repo…

3 confirmed
RFID-03Cross-brand / Protocol · DC Fast Chargers solo+

Local list full — new cards fail

Local list full — new cards fail: charger or site equipment presents this pattern under load or on session start. Techs …

3 confirmed
ALP-HYC-PAYAlpitronic · HYC300 · Payment terminals solo+

Payment terminal offline

Payment terminal offline on alpitronic (hypercharger-hyc300): Hypercharger HMI shows ALP-HYC-PAY. Techs see session abor…

2 confirmed
ABB-T184-COOLABB · Terra 184 · Liquid coolingFree sample

Coolant flow low

Coolant flow low on abb (terra-184): ABB Terra HMI fault banner + service menu shows ABB-T184-COOL. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ABB Connected Services / OCPP StatusNotification info before opening the cabinet.

2 confirmed
NET-C04Cross-brand / Protocol · DC Fast Chargers solo+

Proxy MITM breaks certificate pin

Proxy MITM breaks certificate pin: charger or site equipment presents this pattern under load or on session start. Techs…

3 confirmed
CCS-H10Cross-brand / Protocol · Cables & connectors solo+

SessionSetup ResponseCode Failed

SessionSetup ResponseCode Failed: charger or site equipment presents this pattern under load or on session start. Techs …

2 confirmed
CMS-SCHEDAmpcontrol · Fleet CMS solo+

Schedule blocks depot overnight

Schedule blocks depot overnight: charger or site equipment presents this pattern under load or on session start. Techs r…

1 confirmed
KEM-SAT-LINKKempower · Satellite · DC Fast ChargersFree sample

Satellite link to power unit lost

Satellite link to power unit lost on kempower (satellite): Kempower Satellite / C-series UI shows KEM-SAT-LINK. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate Kempower ChargEye / OCPP before opening the cabinet.

3 confirmed
CP-E250-COMMChargePoint · Express 250 · DC Fast Chargers solo+

Dispenser-cabinet CAN loss

Dispenser-cabinet CAN loss on chargepoint (express-250): ChargePoint station HMI / Cloud diagnostics shows CP-E250-COMM.…

3 confirmed
MET-02Cross-brand / Protocol · DC Fast Chargers solo+

CT polarity reversed after service

CT polarity reversed after service: charger or site equipment presents this pattern under load or on session start. Tech…

2 confirmed
TRI-PK-CABLETritium · PK350 · Liquid coolingFree sample

Liquid-cooled cable leak detect

Liquid-cooled cable leak detect on tritium (pk350): Tritium dispenser UI / RTM or PK service LED shows TRI-PK-CABLE. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate Tritium Veefil / OCPP vendor DataTransfer if enabled before opening the cabinet.

3 confirmed
ABB-T54-ISOABB · Terra 54 · DC Fast ChargersFree sample

Isolation error before charge

Isolation error before charge on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-ISO. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ABB Connected Services / OCPP StatusNotification info before opening the cabinet.

2 confirmed
TEMP-02Cross-brand / Protocol · DC Fast Chargers solo+

Inlet air filter clog false overtemp

Inlet air filter clog false overtemp: charger or site equipment presents this pattern under load or on session start. Te…

3 confirmed
CCS-H07Cross-brand / Protocol · Cables & connectors solo+

PP resistor out of range

PP resistor out of range: charger or site equipment presents this pattern under load or on session start. Techs report i…

2 confirmed
AUT-MC-NACSAutel · MaxiCharger DC · DC Fast Chargers solo+

NACS port latch

NACS port latch on autel (maxicharger-dc): MaxiCharger DC screen shows AUT-MC-NACS. Techs see session abort or stall Una…

2 confirmed
TRI-PK-ISOTritium · PK350 · DC Fast ChargersFree sample

PK350 isolation fault

PK350 isolation fault on tritium (pk350): Tritium dispenser UI / RTM or PK service LED shows TRI-PK-ISO. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate Tritium Veefil / OCPP vendor DataTransfer if enabled before opening the cabinet.

1 confirmed
CHA-H02Cross-brand / Protocol · Cables & connectors solo+

CHAdeMO connector lock fail

CHAdeMO connector lock fail: charger or site equipment presents this pattern under load or on session start. Techs repor…

1 confirmed
SCH-EV-HMISchneider Electric · EVlink · AC Level 2 solo+

LED status stuck red

LED status stuck red: charger or site equipment presents this pattern under load or on session start. Techs report inter…

1 confirmed
COOL-PUMPSite stack (generic) · Coolant skid · Liquid cooling solo+

Coolant pump no flow

Coolant pump no flow on site-generic: Site LMS / breaker / skid local indicators shows COOL-PUMP. Techs see session abor…

3 confirmed
BLK-IQ-NETBlink · IQ 200 · AC Level 2 solo+

Blink network offline

Blink network offline: charger or site equipment presents this pattern under load or on session start. Techs report inte…

2 confirmed
MET-03Cross-brand / Protocol · DC Fast Chargers solo+

kWh under-report vs utility CT

kWh under-report vs utility CT: charger or site equipment presents this pattern under load or on session start. Techs re…

3 confirmed
NET-C05Cross-brand / Protocol · DC Fast Chargers solo+

MTU black hole on cellular path

MTU black hole on cellular path: charger or site equipment presents this pattern under load or on session start. Techs r…

3 confirmed
TEMP-03Cross-brand / Protocol · DC Fast Chargers solo+

Sun load derate on unshaded cabinet

Sun load derate on unshaded cabinet: charger or site equipment presents this pattern under load or on session start. Tec…

3 confirmed
ISO-H04Cross-brand / Protocol · Cables & connectors solo+

CertificateInstallation rejected

CertificateInstallation rejected: charger or site equipment presents this pattern under load or on session start. Techs …

3 confirmed
TRI-PK-GUNTritium · PK350 · DC Fast Chargers solo+

Gun temperature derate

Gun temperature derate on tritium (pk350): Tritium dispenser UI / RTM or PK service LED shows TRI-PK-GUN. Techs see sess…

3 confirmed
CHA-H01Cross-brand / Protocol · Cables & connectorsFree sample

CHAdeMO CAN timeout

CHAdeMO CAN timeout on protocol: CSMS StatusNotification + connector LEDs shows CHA-H01. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate OCPP websocket / SECC / vehicle logs as applicable before opening the cabinet.

2 confirmed
SWG-DOOREaton · Switchgear solo+

Gear door interlock

Gear door interlock: charger or site equipment presents this pattern under load or on session start. Techs report interm…

2 confirmed
CP-E250-RFIDChargePoint · Express 250 · DC Fast Chargers solo+

Station RFID unresponsive

Station RFID unresponsive on chargepoint (express-250): ChargePoint station HMI / Cloud diagnostics shows CP-E250-RFID. …

1 confirmed
FLO-ST-PILOTFlo · Smart Two · AC Level 2 solo+

Pilot diode fail

Pilot diode fail: charger or site equipment presents this pattern under load or on session start. Techs report intermitt…

3 confirmed
RFID-02Cross-brand / Protocol · DC Fast Chargers solo+

RFID works offline but CSMS rejects

RFID works offline but CSMS rejects: charger or site equipment presents this pattern under load or on session start. Tec…

2 confirmed
BESS-FIREFluence / BESS · BESS solo+

Fire panel inhibits charge

Fire panel inhibits charge: charger or site equipment presents this pattern under load or on session start. Techs report…

1 confirmed