The EVSE DirectorySubscribe

Fault database

Search by code, symptom, brand, category, or connector. Full procedures gated by subscription — look for green Free sample badges for open procedures.

Viewing as free

212 results · page 2 of 6

TEMP-02Cross-brand / Protocol · DC Fast ChargersFree sample

Inlet air filter clog false overtemp

Inlet air filter clog false overtemp (TEMP-02) — Thermal / ambient field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

3 confirmed
RFID-01Cross-brand / Protocol · DC Fast ChargersFree sample

RFID reader no UID

RFID reader no UID (RFID-01) — RFID / auth field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
RFID-02Cross-brand / Protocol · DC Fast Chargers solo+

RFID works offline but CSMS rejects

RFID works offline but CSMS rejects (RFID-02) — RFID / auth field fault. Stay OEM-agnostic until the protocol stage pins…

2 confirmed
CLK-01Cross-brand / Protocol · DC Fast Chargers solo+

Clock skew breaks TLS / auth tokens

Clock skew breaks TLS / auth tokens — station time wrong enough that certificates or token windows fail, producing Soft-…

2 confirmed
CFG-01Cross-brand / Protocol · DC Fast ChargersFree sample

Wrong OCPP URL after board swap

Wrong OCPP URL after board swap — new controller still points at lab/staging or old CSMS, so production Cloud never sees the charger. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on CFG-01.

3 confirmed
CFG-02Cross-brand / Protocol · DC Fast ChargersFree sample

Connector ID mismatch dual-gun cabinet

Connector ID mismatch dual-gun cabinet (CFG-02) — Configuration field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
CFG-03Cross-brand / Protocol · DC Fast ChargersFree sample

Power module map incorrect after expansion

Power module map incorrect after expansion (CFG-03) — Configuration field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
VEH-X01Cross-brand / Protocol · Cables & connectors solo+

Known vehicle profile needs CCS pause workaround

Known vehicle profile needs CCS pause workaround (VEH-X01) — Vehicle profile field fault. Stay OEM-agnostic until the pr…

1 confirmed
VEH-X02Cross-brand / Protocol · Cables & connectors solo+

Legacy CHAdeMO only vehicles on CCS site

Legacy CHAdeMO only vehicles on CCS site (VEH-X02) — Vehicle profile field fault. Stay OEM-agnostic until the protocol s…

2 confirmed
VEH-X03Cross-brand / Protocol · Cables & connectors solo+

NACS native vehicle on CCS1-only dispenser

NACS native vehicle on CCS1-only dispenser (VEH-X03) — Vehicle profile field fault. Stay OEM-agnostic until the protocol…

3 confirmed
OCPP-F11Cross-brand / Protocol · DC Fast ChargersFree sample

StopTransaction id mismatch

StopTransaction id mismatch — stop fails or CSMS alarms because transactionId/idTag does not match the open transaction. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on OCPP-F11.

1 confirmed
OCPP-F12Cross-brand / Protocol · DC Fast ChargersFree sample

GetConfiguration key unknown storm

GetConfiguration key unknown storm — CSMS polls unsupported keys, filling logs and sometimes slowing the charger’s OCPP task. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on OCPP-F12.

1 confirmed
CCS-H09Cross-brand / Protocol · Cables & connectorsFree sample

SECC discovery wrong IP

SECC discovery wrong IP — vehicle cannot find SECC on the expected link-local/IP path; handshake dies at discovery/SDP. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on CCS-H09.

2 confirmed
CCS-H10Cross-brand / Protocol · Cables & connectorsFree sample

SessionSetup ResponseCode Failed

SessionSetup ResponseCode Failed (CCS-H10) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
NACS-H04Cross-brand / Protocol · Cables & connectorsFree sample

NACS PP open mid-session

NACS PP open mid-session (NACS-H04) — NACS path field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
ISO-H04Cross-brand / Protocol · Cables & connectors solo+

CertificateInstallation rejected

CertificateInstallation rejected (ISO-H04) — ISO 15118 / PnC field fault. Stay OEM-agnostic until the protocol stage pin…

3 confirmed
CHA-H04Cross-brand / Protocol · Cables & connectors solo+

CHAdeMO available current zero

CHAdeMO available current zero (CHA-H04) — CHAdeMO field fault. Stay OEM-agnostic until the protocol stage pins a hardwa…

1 confirmed
NET-C05Cross-brand / Protocol · DC Fast ChargersFree sample

MTU black hole on cellular path

MTU black hole on cellular path — large OCPP frames fail while tiny pings seem fine; Boot/FW/MeterValues flake on LTE. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on NET-C05.

3 confirmed
LOAD-03Cross-brand / Protocol · Power cabinet / LMS solo+

LMS priority starves fleet overnight

LMS priority starves fleet overnight (LOAD-03) — Load management field fault. Stay OEM-agnostic until the protocol stage…

2 confirmed
GND-03Cross-brand / Protocol · DC Fast Chargers solo+

Bond jumper missing at pedestal

Bond jumper missing at pedestal (GND-03) — Ground / isolation field fault. Stay OEM-agnostic until the protocol stage pi…

2 confirmed
RFID-03Cross-brand / Protocol · DC Fast Chargers solo+

Local list full — new cards fail

Local list full — new cards fail (RFID-03) — RFID / auth field fault. Stay OEM-agnostic until the protocol stage pins a …

3 confirmed
CFG-04Cross-brand / Protocol · DC Fast ChargersFree sample

Wrong timezone breaks TOU LMS

Wrong timezone breaks TOU LMS (CFG-04) — Configuration field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
MET-03Cross-brand / Protocol · DC Fast Chargers solo+

kWh under-report vs utility CT

kWh under-report vs utility CT (MET-03) — Metering field fault. Stay OEM-agnostic until the protocol stage pins a hardwa…

3 confirmed
TEMP-03Cross-brand / Protocol · DC Fast Chargers solo+

Sun load derate on unshaded cabinet

Sun load derate on unshaded cabinet (TEMP-03) — Thermal / ambient field fault. Stay OEM-agnostic until the protocol stag…

3 confirmed
OCPP-F13Cross-brand / Protocol · DC Fast ChargersFree sample

ChangeAvailability rejected while charging

ChangeAvailability rejected while charging — ops tries to set Inoperative mid-session and charger correctly rejects, or rejects even when idle due to state desync. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on OCPP-F13.

2 confirmed
CCS-H11Cross-brand / Protocol · Cables & connectorsFree sample

EVSideCableCheck unknown error

EVSideCableCheck unknown error (CCS-H11) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
NET-C06Cross-brand / Protocol · DC Fast ChargersFree sample

CSMS rate-limits StatusNotification

CSMS rate-limits StatusNotification — after a reconnect storm the CSMS throttles, chargers appear offline/Faulted in UI despite healthy hardware. protocol field note: keep evidence scrubbed and prove the ranked cause before module RMA on NET-C06.

1 confirmed
CP-E250-GFChargePoint · Express 250 · DC Fast ChargersFree sample

Ground fault trip under rain

Express 250 ground-fault trip under rain, wash-down, or wet holster — Cloud Faulted and local GF latch may refuse clear until the moisture path is proven dry. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-E250-GF.

2 confirmed
CP-E250-ISOChargePoint · Express 250 · DC Fast ChargersFree sample

Isolation fault after cable swap

Express 250 isolation fault before or during CableCheck after a cable swap, rain, or cooled-cable service — one gun or whole power cabinet. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-E250-ISO.

1 confirmed
CP-E250-FANChargePoint · Express 250 · DC Fast Chargers solo+

Power module fan fail

Express 250 power-module fan fail or thermal derate — loud/stopped fan, elevated module temps, or Cloud thermal events w…

2 confirmed
CP-E250-COMMChargePoint · Express 250 · DC Fast Chargers solo+

Dispenser-cabinet CAN loss

Express 250 dispenser–cabinet CAN/comm loss — dispenser UI dead or offline while the cabinet is still powered, or Cloud …

3 confirmed
CP-E250-DOORChargePoint · Express 250 · DC Fast Chargers solo+

Cabinet door interlock open

Express 250 cabinet door interlock open — station refuses energy or Faults while the door switch reports open even when …

2 confirmed
CP-E250-PFCChargePoint · Express 250 · DC Fast ChargersEarly access pro+

PFC stage overcurrent

ChargePoint PFC stage overcurrent (CP-E250-PFC) — confirm Express power cabinet vs dispenser ownership before parts. Fie…

1 confirmed
CP-E250-HDCChargePoint · Express 250 · DC Fast ChargersEarly access pro+

HDC contactor weld detect

ChargePoint HDC contactor weld detect (CP-E250-HDC) — confirm Express power cabinet vs dispenser ownership before parts.…

2 confirmed
CP-E250-RFIDChargePoint · Express 250 · DC Fast Chargers solo+

Station RFID unresponsive

Express 250 station RFID unresponsive — badge taps ignored while FreeVend or remote start may still work, pointing at th…

1 confirmed
CP-XP-COOLChargePoint · Express Plus · Liquid coolingEarly access pro+

Liquid cooling pump fail

ChargePoint Liquid cooling pump fail (CP-XP-COOL) — confirm Express power cabinet vs dispenser ownership before parts. F…

2 confirmed
CP-XP-NACSChargePoint · Express Plus · DC Fast ChargersFree sample

NACS port overtemp

Express Plus NACS port overtemp / derate — handle or inlet temps climb, session throttles or Faults, often in sun or after damaged handle work. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-XP-NACS.

3 confirmed
CP-XP-MODChargePoint · Express Plus · DC Fast ChargersEarly access pro+

Power brick offline

ChargePoint Power brick offline (CP-XP-MOD) — confirm Express power cabinet vs dispenser ownership before parts. Field t…

2 confirmed
CP-XP-LMSChargePoint · Express Plus · DC Fast Chargers solo+

Site LMS curtails Express Plus

Site LMS curtails Express Plus to near-zero amps — stalls look Faulted/Unavailable while power hardware is healthy and L…

3 confirmed
CP-XP-PAYChargePoint · Express Plus · Payment terminals solo+

Payment authorize timeout

Express Plus payment authorize timeout — PED spins or declines while FreeVend/RFID may work, splitting money path from e…

2 confirmed