Fault database

Search by code, symptom, brand, category, or connector. Full procedures gated by subscription — look for green Free sample badges for open procedures.

Viewing as free

21 results for “isolation”

CCS-H03Cross-brand / Protocol · Cables & connectorsFree sample

Cable check isolation fail

Cable check isolation fail (CCS-H03) — CCS handshake field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
GND-01Cross-brand / Protocol · DC Fast ChargersFree sample

Ground continuity fail at dispenser

Ground continuity fail at dispenser (GND-01) — Ground / isolation field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

1 confirmed
GND-02Cross-brand / Protocol · DC Fast ChargersFree sample

Isolation monitor nuisance trip wet weather

Isolation monitor nuisance trip wet weather (GND-02) — Ground / isolation field fault. Stay OEM-agnostic until the protocol stage pins a hardware path; capture SECC/OCPP/vehicle evidence before opening the cabinet.

2 confirmed
GND-03Cross-brand / Protocol · DC Fast Chargers solo+

Bond jumper missing at pedestal

Bond jumper missing at pedestal (GND-03) — Ground / isolation field fault. Stay OEM-agnostic until the protocol stage pi…

2 confirmed
CP-E250-ISOChargePoint · Express 250 · DC Fast ChargersFree sample

Isolation fault after cable swap

Express 250 isolation fault before or during CableCheck after a cable swap, rain, or cooled-cable service — one gun or whole power cabinet. chargepoint field note: keep evidence scrubbed and prove the ranked cause before module RMA on CP-E250-ISO.

1 confirmed
ABB-T54-ISOABB · Terra 54 · DC Fast ChargersFree sample

Isolation error before charge

Terra 54 isolation error before charge — rain/cable/ISO path before power module blame. Field techs should correlate HMI/Cloud timestamps with Verify which gun and which stack faulted on dual-standard Terra sites.

2 confirmed
TRI-PK-ISOTritium · PK350 · DC Fast ChargersFree sample

PK350 isolation fault

PK350 isolation fault — cooled-cable/moisture path; PK liquid-cooled rules differ from RTM air-cooled. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.

1 confirmed
TRI-PK-CABLETritium · PK350 · Liquid coolingFree sample

Liquid-cooled cable leak detect

PK350 liquid-cooled cable leak detect — contain spill, reseal/replace path, bleed before return to service. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.

3 confirmed
TRI-PK-DISPTritium · PK350 · DC Fast Chargers solo+

Dispenser UI no boot

PK dispenser UI no boot — HMI/SBC path while power cabinet may still be alive. Field techs should correlate HMI/Cloud ti…

2 confirmed
TRI-PK-PWRTritium · PK350 · DC Fast ChargersEarly access pro+

Rectifier stage fault

PK rectifier stage fault — early-access HV power stage; LOTO and OEM diagnostics. Field techs should correlate HMI/Cloud…

3 confirmed
TRI-PK-NETTritium · PK350 · DC Fast ChargersEarly access pro+

Cellular failover flapping

PK cellular failover flapping — early-access modem/SIM/DNS path before board RMA. Field techs should correlate HMI/Cloud…

1 confirmed
TRI-PK-GUNTritium · PK350 · DC Fast Chargers solo+

Gun temperature derate

PK gun temperature derate — handle/contact heat or sensor; sun and damaged guns rank high. Field techs should correlate …

3 confirmed
TRI-RTM-GFTritium · RTM75 · DC Fast ChargersFree sample

RTM ground fault

RTM ground fault — air-cooled RTM: moisture/cable/PE; do not bleed coolant on RTM air path. Field techs should correlate HMI/Cloud timestamps with PK liquid-cooled path vs RTM air-cooled path changes isolation and thermal triage.

3 confirmed
TRI-RTM-FANTritium · RTM75 · DC Fast Chargers solo+

Inlet fan blocked

RTM inlet fan blocked — thermal path on air-cooled RTM; clean inlet before sensor swaps. Field techs should correlate HM…

3 confirmed
TRI-RTM-AUTHTritium · RTM75 · DC Fast Chargers solo+

Auth timeout local list empty

RTM auth timeout local list empty — offline auth cache/CSMS list, not power electronics. Field techs should correlate HM…

2 confirmed
TRI-RTM-CANTritium · RTM75 · DC Fast ChargersEarly access pro+

Internal CAN bus error

RTM internal CAN bus error — early-access internal comms; reseat/OEM. Field techs should correlate HMI/Cloud timestamps …

1 confirmed
BTC-HP-ISOBTC Power · HP150 · DC Fast ChargersFree sample

HP150 isolation trip

BTC HP150 isolation trip — cable/moisture/ISO path on HP family before power-module crates. Field techs should correlate HMI/Cloud timestamps with HP family often needs power-cabinet vs dispenser CAN check before module swap

1 confirmed
ALP-HYC-ISOAlpitronic · HYC300 · DC Fast ChargersFree sample

HYC isolation fault

Alpitronic Hypercharger fails isolation during CableCheck on one connector, or occasionally across the whole cabinet, most often after rain, a cable swap, or overnight condensation. Because HYC300 modules share a common coolant loop, a wet or contaminated path on one gun can occasionally present as a broader isolation issue across the bank.

2 confirmed
AUT-MC-ISOAutel · MaxiCharger DC · DC Fast ChargersFree sample

MaxiCharger isolation

Autel MaxiCharger DC fails isolation/CableCheck on one connector while the peer port on the same dual-standard unit stays healthy. Because MaxiCharger DC often pairs a CCS and NACS port from a shared cabinet, techs must confirm which physical port and which cable actually failed before assuming a cabinet-wide isolation fault.

3 confirmed
SIE-SD-ISOSiemens · Sicharge D · DC Fast ChargersFree sample

Sicharge isolation

Siemens Sicharge D reports an isolation fault on one connector path while the peer gun on the same cabinet may remain Available, and technicians must confirm whether the power cabinet or the dispenser head owns the failing measurement before opening either enclosure. Weather exposure and recent cable service are the most common triggers.

1 confirmed
PE-NB-ISOPower Electronics · NB 360 · DC Fast ChargersFree sample

NB360 isolation

Power Electronics NB360 fails isolation during CableCheck, and because the NB360 cabinet uses a multi-module current-share architecture, technicians must confirm whether the fault traces to a single module's contribution or the shared measurement path before opening the whole cabinet. Cable moisture and single-module contamination are the two leading field causes.

2 confirmed